The determination of serum magnesium by the molybdivanadate method for phosphate.

نویسندگان

  • D G SIMONSEN
  • L M WESTOVER
  • M WERTMAN
چکیده

During the past decade there has been an increasing interest shown in the study of electrolyte balance. Magnesium, however, has played a minor r81e in these studies. There are perhaps two reasons for this; first, that serum magnesium levels remain fairly constant and, second, that magnesium determinations require special technique and equipment and are time-consuming procedures as well. There have been three major methods used for the determination of serum magnesium, the molybdenum blue, titan yellow, and hydroxyquinoline methods. Molybdenum Blue-Briggs (1) and Denis (2) simultaneously reported methods for the determination of serum magnesium based upon the precipitation of magnesium as magnesium ammonium phosphate, with subsequent estimation of the phosphate by the molybdenum blue method. The above procedures were employed in this laboratory with the modifications for phosphate determination used by Kuttner and Cohen (3) and Youngburg and Youngburg (4). The molybdenum blue method was abandoned chiefly because of instability of the color. A more complete discussion of this is given in a publication (5) in which the molybdivanadate method, as outlined by Kitson and Mellon (6), was used for the estimation of serum phosphate. Titan Yellou+The titan yellow method is based on the fact that magnesium imparts a pink color to an alkaline solution of the dye (7). The clinical method of Him&elder and Serles (8) and the modification of Haury (9) were used, but difficulty was encountered because of the mixture of pink and yellow colors. In addition, the color wss markedly affected by variations in pH and salt concentration. Hydrmyquinoline-Hahn (10) and Berg (11) introduced the use of 8-hydroxyquinoline for the determination of magnesium. The method was further modified by the bromination technique of Bomskov (12), Greenberg and Mackey (13), and Velluz (14). Hoffman (15) discarded the bromination method in favor of a calorimetric procedure in which hydroxyquinoline combines with ferric ions in weak hydrochloric acid

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A colorimetric method for the estimation of serum magnesium.

I955 The author wishes to express his sincere appreciation to Dr R. E. Hungate for an introduction to the fascinating cattle protozoa and for many stimulating discussions during the course of the experiments. The investigation was supported in part by funds for biological and medical research by the State of Washington, initiative measure number 171. In clinical work, where general electrolyte ...

متن کامل

A method for the colorimetric determination of calcium and magnesium in small amounts of urine, stool, and food.

This report presents a method for the quantitative determination of magnesium and calcium in a single specimen of urine, stool, and food by formation and calorimetric determination of their respective phosphates. The method makes use of some of the principles advanced by Roe and Kahn (1) for determination of serum calcium, and by Denis (2) for serum magnesium. Phosphorus determinations are perf...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

The determination of metals in blood serum by atomic absorption spectroscopy-II Magnesium

The magnesium content of blood serum may be accurately determined by atomic absorption measurements. Analysis can be carried out on as little as 0.05 ml of serum and the only preliminary treatment necessary is dilution of the sample with water containing about 1 per cent of ethylenediaminetetracetic acid or of strontium chloride. Existing methods for estimation of magnesium THE lack of detailed...

متن کامل

Simplex design method in simultaneous spectrophotometric determination of silicate and phosphate in boiler water of power plant and sewage sample by partial least squares

Partial least squares modeling as a powerful multivariate statistical tool was applied tothe simultaneous spectrophotometric determination of silicate and phosphate in aqueoussolutions. The concentration range for silicate and phosphate were 0.02-0.6 and 0.4-3 μg ml-1,respectively. The experimental calibration set was composed with 30 sample solutions using amixture design for two component mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of biological chemistry

دوره 169 1  شماره 

صفحات  -

تاریخ انتشار 1947