Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures.
نویسندگان
چکیده
OBJECTIVES The aim of this study was to accurately assess the radiation exposure received by patients during cardiac catheterization in a large sample representative of the current state of practice in cardiac angiography. BACKGROUND Radiation exposure to patients and laboratory staff has been recognized as a necessary hazard in coronary angiography. The effects on x-ray exposure of the increased complexity of coronary angiographic procedures and, in particular, the increasing use of coronary artery stenting, have not been adequately addressed in previous studies. METHODS X-ray exposure measurements were performed on a consecutive series of 972 patients undergoing 992 diagnostic and interventional studies in the Mayo Clinic catheterization laboratory within an eight week period in late 1997. Data were acquired from 706 diagnostic procedures and 286 interventional procedures using a real-time exposure measurement system to continuously calculate and record the exposure rate and total exposure, reflecting all parameters relevant to the specific patient and procedure situation. RESULTS The median exposure for all 992 procedures was 41.8 mC/kg (162.1 R); the corresponding values for diagnostic and interventional procedures were 34.9 and 95.6 mC/kg, respectively (135.3 vs. 370.5 R). There were significant differences in the fluoroscopy exposure time between diagnostic and interventional procedures: 4.7 min vs. 21.0 min. Heavier patients (>83 kg) received x-ray exposures at a significantly higher rate than did lighter patients (<83 kg) during both fluoroscopy and cine; 44.9 mC/kg/min (173.9 R/min) vs. 27.9 mC/kg/min (108.3 R/min) for cine exposure rate and 2.3 mC/kg/min (8.8 R/min) vs. 1.5 mC/kg/min (5.8 R/min) for fluoroscopy exposure rate. CONCLUSIONS Changes in practice have led to higher values for patient x-ray radiation exposures during cardiac catheterization procedures. The real-time display and recording of x-ray exposure facilitates the reduction of exposure in the catheterization laboratory.
منابع مشابه
Patient dose values during interventional cardiology examinations in Yazd hospital, Iran
Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...
متن کاملAssessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)
Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...
متن کاملStaff dose assessment from coronary angiography
Background: Interventional cardiology procedures such as coronary angiography (CA) and percutaneous transluminal coronary angiography (PTCA) has been increased recent years. The purpose of this study was to measurement of effective dose to cardiology staffs who operate near the patient and are exposed to non-uniform radiation field due to patient scattered radiation. Materials and Methods: This...
متن کاملAssessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran
Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...
متن کاملPatient Radiation Doses in Interventional Cardiology Procedures
Interventional cardiology procedures result in substantial patient radiation doses due to prolonged fluoroscopy time and radiographic exposure. The procedures that are most frequently performed are coronary angiography, percutaneous coronary interventions, diagnostic electrophysiology studies and radiofrequency catheter ablation. Patient radiation dose in these procedures can be assessed either...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 33 2 شماره
صفحات -
تاریخ انتشار 1999