Design and evaluation of a new fully microwave-assisted liquid sample introduction device for inductively coupled plasma atomic emission spectrometry

نویسندگان

  • Guillermo Grindlay
  • Luis Gras
  • Javier Montiel
  • Vicente Hernandis
  • Juan Mora
چکیده

A new fully microwave-assisted liquid sample introduction system (MASIS) is presented and evaluated in Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The device employs a single TM010 microwave cavity for the simultaneous aerosol generation and desolvation. The different experimental requirements of both physical processes demand a careful system design and a judicious selection of the experimental conditions. The behavior of the MASIS depends on the: (i) microwave power; (ii) nebulizer nozzle inner diameter; (iii) sample uptake rate; and, (iv) matrix nature (i.e. acids, salts) and concentration. Thus, optimum operating conditions are obtained when increasing the microwave power, the matrix concentration and the sample uptake rate as well as when decreasing the nebulizer nozzle inner diameter. The analytical figures of merit afforded by the MASIS in ICP-AES are compared to those obtained with: (1) a pneumatic concentric nebulizer coupled to a cyclonic spray chamber (CS); (2) a microwave thermal nebulizer (MWTN) coupled to a cyclonic spray chamber; and (3) a pneumatic nebulizer coupled to a microwave desolvation system (MWDS). MASIS provides limits of detection up to 50 times lower than those obtained with the CS and up to 8 times lower than those with the MWTN and MWDS. No significant difference in the signal precision between the different devices tested is observed (i.e. 2–5%). Regarding the wash-out times, both MASIS and MWDS show the highest values of this parameter (i.e. 70 s) due to their higher inner volume. Wash-out time values for both MWTN and CS are lower than 30 s.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...

متن کامل

Screening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology

Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Determination of soluble toxic arsenic species in alga samples by microwave-assisted extraction and high performance liquid chromatography-hydride generation-inductively coupled plasma-atomic emission spectrometry

A microwave-based procedure for arsenic species extraction in alga samples (Sargassum fulvellum, Chlorella vulgaris, Hizikia fusiformis and Laminaria digitata) is described. Extraction time and temperature were tested in order to evaluate the extraction efficiency of the process. Arsenic compounds were extracted in 8 ml of deionised water at 90 °C for 5 min. The process was repeated three times...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010