A discordant of blood glucose analysed by Glucometer and the Central lab method in an infant with Galactosemia

نویسندگان

  • Sukumarn Siripunthana
  • Taninee Sahakitrungruang
  • Suttipong Washarasindhu
  • Kanya Suphapeetiporn
  • Vichit Supornsilchai
چکیده

Galactosemia is an autosomal recessive disorder, which caused by a deficiency of one of three enzymes that involved in the metabolism of galactose; galactokinase (GALK), galactose-1-phosphate uridyltransferase (GALT) and uridine-diphosphate galactose-4’epimerase (GALE). Clinical manifestations including poor feeding, jaundice, hepatomegaly, vomiting, hypoglycemia, convulsions, failure to thrive, cataracts, bleeding disorder, renal failure, liver cirrhosis, mental retardation and increased risk for E. coli sepsis,develop after milk feeding. We reported an infant who presented with prolonged hyperbilirubinemia and different result of blood glucose between glucometer and the central lab which is an unusual presentation of galactosemia. A 11day-old male infant born to non-consanguineous parents presented with jaundice, poor feeding, poor weight gain, vomiting and drowsiness when he was 6-day-old. On physical examination revealed lethargic, icteric sclerae and hepatomegaly. Cataract examined by the opththalomologist was not found. Routine work up for the causes of neonatal jaundice was found to be normal. LFTs showed TB of 26.8, DB 3.57 mg/dL, SGOT 82, SGPT 50 and ALP 871U/L. TFTs showed FT4 of 1.62 ng/dL, TSH 4.91 mu/L. Electrolytes and coagulogram were normal. His blood sugar was 220 mg/dL by Glucometer (Accu-chek Performa) without any symptoms and signs of hyperglycemia and glucosuria, but it was 60 mg/dL by the central lab method. Galactosemia was confirmed by the high level of urine Galactitol and the genetic analysis of Galactose-1phosphate uridyl transferase (GALT) found compound heterozygous mutation of p.R259W in exon 8 and p. E340K in exon 10 which is a known mutation. One day after soy-based formula was started, the bilirubin levels were gradually reduced to normal for 1 week and the discrepancy of blood glucose between Glucometer and the central lab method was resolved. Sepsis can not be totally excluded by this clinical setting, antibiotic was started to cover the organism which is common for this age group including E Coli. This paper reported infant with Galactosemia who presented with an unusual finding of the discordance between blood sugar levels analysed by Glucometer and the central lab method due to some Glucometer analyse other form of sugar especially Galactose and its metabolites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

Capillary Bedside Blood Glucose Measurement in Neonates: Missing a Diagnosis of Galactosemia

A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a g...

متن کامل

مقایسه میزان همخوانی یافته‌های سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد

Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...

متن کامل

مقایسه قدرت دستگاه گلوکومتر Accu-chek با Elite در تشخیص دیابت با استفاده از خونریزی متعاقب Probing

Abstract Background: Recent studies have assessed the validity of glucometer devices in estimating the glucose level of gingival blood during routine periodontal examination (Bleeding On Probing). The purpose of this study was to evaluate whether blood oozing from gingival tissues during routine periodontal examination can be used for determining g...

متن کامل

بررسی تغییرات قند خون بیماران قبل، حین و بعد از اعمال جراحی انتخابی چشمی تحت بیهوشی عمومی با دو روش سنجش با گلوکومتر و اندازه گیری آزمایشگاهی

Background: Hyperglycemia is a metabolic response to surgical stress. In this study, patients’ blood glucose changes were measured before, during and after elective eye surgeries under general anesthesia, with two methods: glucometer and glucose oxidase enzyme lab assay. Probable influencing factors and the correlation rate of these two methods were evaluated. Methods: This analytic cross – sec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013