Non-invasive method for rapid bedside estimation of inotropy: theory and preliminary clinical validation.

نویسندگان

  • B E Smith
  • V M Madigan
چکیده

BACKGROUND There are numerous techniques which attempt to quantify inotropy (or myocardial contractility). None has yet found general acceptance in anaesthesia and critical care as a practical method. We report a novel approach to the determination of inotropy as a bedside procedure which could identify low inotropy states in patients with clinical heart failure. METHODS We estimated the potential and kinetic energy delivered by the left ventricle using continuous-wave Doppler ultrasound (ultrasonic cardiac output monitor, Uscom, Sydney, Australia) and data available at the point of care. A formula to calculate effective inotropy [Smith-Madigan inotropy index (SMII)] was tested against historical haemodynamic data for 250 control subjects (ASA I patients from preoperative clinic) and 83 patients with acute left ventricular failure (LVF) of New York Heart Association Grade 4 (LVF group). The ratio of potential to kinetic energy (PKR) was investigated as a measure of arterial impedance. RESULTS Significant differences were found between the control and LVF groups for cardiac index, mean (range)=3.37 (2.84-5.32) vs 1.84 (1.43-2.26) litre min(-1) m(-2); stroke volume index (SVI), 49.2 (39-55) vs 34.3 (23-37) ml m(-2); systemic vascular resistance, 893 (644-1242) vs 1960 (1744-4048) dyn s cm(-5); SMII, 1.78 (1.35-2.24) vs 0.73 (0.43-0.97) W m(-2); and PKR, 29:1 (24-35:1) vs 124:1 (96-174:1), P<0.001 in each case. Normal ranges were calculated for SMII and PKR as mean (+/-1.96) standard deviations, yielding 1.6-2.2 W m(-2) for SMII, and 25-34:1 for PKR. CONCLUSION The method clearly identified the two clinical groups with no overlap of data points. The discriminant power of SMII and PKR may offer valuable diagnostic methods and monitoring tools in anaesthesia and critical care. This is the first report of normal ranges for SMII and PKR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of breast cancer using non-invasive X-ray diffraction technique of hair: A preliminary study

Background: An early diagnosis of breast cancer relates directly to an accurate treatment plan and strategy. Early detection of breast cancer before its development would be a significant reduction of morbidity and mortality rates. The aim of this preliminary study is to investigate the sensitivity of Wide Angle X-ray diffraction (WAXRD) method on women hair samples of healthy and breast cancer...

متن کامل

Comparing Invasive and Non-Invasive of Isolated Shigella flexneri by Electron Microscopy of Cell Culture, SDS-PAGE and Congo Red Method

The aim of this study was to compare invasive and non-invasive strains of Shigella flexneri isolated from Tehran by a 120 kDa protein band by SDS-PAGE, electron microscopy of cell culture and Congo red dye methods. Methods: S. flexneri strains were isolated by standard bacterial methods from fecal specimens of children attending to the 3 children’s hospitals. Phenotype analysis for screening v...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

Large-scale Inversion of Magnetic Data Using Golub-Kahan Bidiagonalization with Truncated Generalized Cross Validation for Regularization Parameter Estimation

In this paper a fast method for large-scale sparse inversion of magnetic data is considered. The L1-norm stabilizer is used to generate models with sharp and distinct interfaces. To deal with the non-linearity introduced by the L1-norm, a model-space iteratively reweighted least squares algorithm is used. The original model matrix is factorized using the Golub-Kahan bidiagonalization that proje...

متن کامل

Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis

In this study, a method for non-invasive estimation of stress on the heart wall in  the diastole phase is presented using ultrasound echocardiography and tissue Doppler  imaging. The aim of this study was to evaluate the stress on the heart wall as a  pre-diagnosis  to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 111 4  شماره 

صفحات  -

تاریخ انتشار 2013