Interscan registration using navigator echoes.
نویسندگان
چکیده
A common problem in clinical MRI is anatomic misalignment of imaging slices across successive examinations. This unnecessarily complicates the radiologic assessment of anatomic change over time on serial MRI studies. To address this problem, spherical navigator echoes, which can detect rigid body motion in all six degrees of freedom, were used to guide spatial location and orientation adjustments to an exam prescription to match the reference frame of images acquired in an earlier exam. An initial linear navigator echo is also necessary to effect coarse Z translation adjustments prior to fine six degrees of freedom adjustment with a spherical navigator echo. Results of this technique are presented for head image volumes of five volunteers. Each volunteer was imaged on two scanners. In all cases, the reference frame adjustments provided by the navigator echoes substantially improved the alignment of the latter exam and performed well compared to retrospective image-based registration.
منابع مشابه
Variable-Density Oblique Spherical Navigator Echoes to Improve Performance in Measuring 3D Motion
A. F. Costa, D. Petrie, M. Drangova Robarts Research Institute, London, Ontario, Canada, Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada Introduction: Correcting for subject motion remains a challenging problem in Magnetic Resonance Imaging. One-dimensional navigator echoes have been used successfully in a number of applications, but can only measure...
متن کاملNavigator-Free Dynamic Phase Correction for Echo-Planar Imaging Based Functional MRI
INTRODUCTION In dynamic echo-planar imaging (EPI), such as functional MRI, where a time series of EPI images are collected, there is additional modulation along echo readout due to changes in hardware states (e.g., temperature) that the standard reference scan based phase correction methods [1-3] cannot account for, thereby resulting in an increase of ghost level over time. To address this prob...
متن کاملReal-Time Navigator Approach to Motion Problems in Coronary MRA
This paper is a summary discourse on the real time navigator approach to suppressing motion effects in coronary magnetic resonance angiography. The concept of navigator approach, characteristics of coronary motion, design of navigator echoes for motion measurements, and navigator algorithms for motion effects suppression are reviewed and discussed. At the conclusion, an efficient and effective ...
متن کاملNavigator echoes in cardiac magnetic resonance.
Navigator echoes are frequently used in cardiac magnetic resonance to monitor respiratory motion and have proved particularly useful in coronary artery imaging techniques where they allow the acquisition of data over multiple reproducible breathholds and during free breathing. The large number of variables involved in their use, however, is such that an optimal method of application may yet hav...
متن کاملCorrection for Involuntary Motion Related Artifacts in Multi-Shot EPI using k-space Data Swapping
Phase corrections based on readout-asymmetry and navigatorechoes can effectively reduce the motion-related phase errors in multi-shot EPI for diffusion weighted imaging studies. However, occasional involuntary motions might be too severe to be corrected by the navigator echoes. To minimize this effect, kspace data swapping technique is proposed in this study. By replacing the corrupted k-space ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 52 6 شماره
صفحات -
تاریخ انتشار 2004