Diastolic time – frequency relation in the stress echo lab: filling timing and flow at different heart rates

نویسندگان

  • Tonino Bombardini
  • Vincenzo Gemignani
  • Elisabetta Bianchini
  • Lucia Venneri
  • Christina Petersen
  • Emilio Pasanisi
  • Lorenza Pratali
  • David Alonso-Rodriguez
  • Mascia Pianelli
  • Francesco Faita
  • Massimo Giannoni
  • Giorgio Arpesella
  • Eugenio Picano
چکیده

UNLABELLED A cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been recently validated. Second heart sound can be simultaneously recorded in order to quantify both systole and diastole duration. AIMS 1- To assess the feasibility and extra-value of operator-independent, force sensor-based, diastolic time recording during stress. METHODS We enrolled 161 patients referred for stress echocardiography (exercise 115, dipyridamole 40, pacing 6 patients).The sensor was fastened in the precordial region by a standard ECG electrode. The acceleration signal was converted into digital and recorded together with ECG signal. Both systolic and diastolic times were acquired continuously during stress and were displayed by plotting times vs. heart rate. Diastolic filling rate was calculated as echo-measured mitral filling volume/sensor-monitored diastolic time. RESULTS Diastolic time decreased during stress more markedly than systolic time. At peak stress 62 of the 161 pts showed reversal of the systolic/diastolic ratio with the duration of systole longer than diastole. In the exercise group, at 100 bpm HR, systolic/diastolic time ratio was lower in the 17 controls (0.74 +/- 0.12) than in patients (0.86 +/- 0.10, p < 0.05 vs. controls). Diastolic filling rate increased from 101 +/- 36 (rest) to 219 +/- 92 ml/m2* s-1 at peak stress (p < 0.5 vs. rest). CONCLUSION Cardiological systolic and diastolic duration can be monitored during stress by using an acceleration force sensor. Simultaneous calculation of stroke volume allows monitoring diastolic filling rate.Stress-induced "systolic-diastolic mismatch" can be easily quantified and is associated to several cardiac diseases, possibly expanding the spectrum of information obtainable during stress.

منابع مشابه

Frequency-based analysis of the early rapid filling pressure-flow relation elucidates diastolic efficiency mechanisms.

Stiffness- and relaxation-based diastolic function (DF) assessment can characterize the presence, severity, and mechanism of dysfunction. Although frequency-based characterization of arterial function is routine (input impedance, characteristic impedance, arterial wave reflection), DF assessment via frequency-based methods incorporating optimization/efficiency criteria is lacking. By definition...

متن کامل

WEB downloadable software for training in cardiovascular hemodynamics in the (3-D) stress echo lab

When a physiological (exercise) stress echo is scheduled, interest focuses on wall motion segmental contraction abnormalities to diagnose ischemic response to stress, and on left ventricular ejection fraction to assess contractile reserve. Echocardiographic evaluation of volumes (plus standard assessment of heart rate and blood pressure) is ideally suited for the quantitative and accurate calcu...

متن کامل

Cardiac reflections and natural vibrations: Force-frequency relation recording system in the stress echo lab

BACKGROUND The inherent ability of ventricular myocardium to increase its force of contraction in response to an increase in contraction frequency is known as the cardiac force-frequency relation (FFR). This relation can be easily obtained in the stress echo lab, where the force is computed as the systolic pressure/end-systolic volume index ratio, and measured for increasing heart rates during ...

متن کامل

Post-exercise contractility, diastolic function, and pressure: Operator-independent sensor-based intelligent monitoring for heart failure telemedicine

BACKGROUND New sensors for intelligent remote monitoring of the heart should be developed. Recently, a cutaneous force-frequency relation recording system has been validated based on heart sound amplitude and timing variations at increasing heart rates. AIM To assess sensor-based post-exercise contractility, diastolic function and pressure in normal and diseased hearts as a model of a wireles...

متن کامل

Assessment of left ventricular pressure-volume relations using gated radionuclide angiography, echocardiography, and micromanometer pressure recordings. A new method for serial measurements of systolic and diastolic function in man.

This study was designed to validate the use of combined invasive and noninvasive methods in assessing serial pressure-volume relations in man. Ten patients undergoing cardiac catheterization were studied with simultaneous intracardiac micromanometer pressure recordings, gated radionuclide angiography and echocardiography. Systolic and diastolic function were measured at rest, during right atria...

متن کامل