Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique.
نویسندگان
چکیده
BACKGROUND The rope-ladder puncture technique, with cannulation along the whole length of the vessel traject, has been very common in haemodialysis patients with autogenous arterio-venous fistula (AVF). Today's dialysis population with AVF may exhibit difficult cannulation, because of a short vein length or a complicated cannulation route. An alternative needling possibility is the buttonhole (BH) technique, which inserts needles at exactly the same location during every dialysis session. The present study was conducted to investigate the effect of both cannulation techniques on the incidence of vascular access (VA) complications. METHODS A total of 75 prevalent haemodialysis patients with autogenous AVF using the BH technique were compared with 70 patients using the rope-ladder technique. The following parameters were registered: haematoma occurrence, redness, swelling, aneurysm formation, the use of sharp or dull needles, miscannulations, and interventions. Needling pain and fear of puncture were assessed using a verbal rating scale (VRS). The duration of the follow-up was 9 months. RESULTS Patients in the BH group had more unsuccessful cannulations, compared with the rope-ladder method (P < 0.0001), but the frequency of haematoma (P < 0.0001) and aneurysm formation (P < 0.0001) was less. In addition, intervention such as angioplasty (P < 0.0001) was higher in patients using the rope-ladder technique. A negative outcome of the BH technique was the higher incidence of access infections compared to the rope-ladder method. CONCLUSION This study showed that the BH method is a valuable technique with few complications like haematoma, aneurysm formation and the need for interventions. However, the infections induced by the BH method should not be underestimated. This underlines the importance of an aseptic and correct technique of the buttonhole procedure.
منابع مشابه
Cannulating in haemodialysis: rope-ladder or buttonhole technique?
BACKGROUND The standard technique for fistula cannulation, the rope-ladder technique, is problematic for patients with short fistula lengths and for patients in whom the fistula is difficult to cannulate. The buttonhole technique, cannulation of exactly the same site, offers the advantage of an easy cannulation procedure. However, it can be used only in native fistulas and cannulation is prefer...
متن کاملArterio-venous fistula buttonhole cannulation technique: a retrospective analysis of infectious complications
BACKGROUND There are two main methods of accessing arterio-venous fistulas (AVFs); the 'buttonhole' and the 'rope-ladder' cannulation technique. Several small studies have hypothesized that the buttonhole technique is associated with increased rates of fistula-associated infection. This study addresses this hypothesis. METHODS A retrospective review of all patients attending a large outpatien...
متن کاملButtonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.
BACKGROUND AND OBJECTIVES The relative merits of buttonhole (or blunt needle) versus rope ladder (or sharp needle) cannulation for hemodialysis vascular access are unclear. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Clinical outcomes by cannulation method were reviewed in 90 consecutive home hemodialysis patients. Initially, patients were trained in rope ladder cannulation. From 2004 on, a...
متن کاملButtonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.
BACKGROUND The buttonhole technique is an alternative method of cannulating the arteriovenous fistula (AVF) in hemodialysis (HD), frequently used for home HD patients. However, the balance of risks and benefits of the buttonhole compared with the rope-ladder technique is uncertain. STUDY DESIGN A systematic review of randomized trials and observational studies (case reports, case series, stud...
متن کاملA randomized trial comparing buttonhole with rope ladder needling in conventional hemodialysis patients.
BACKGROUND AND OBJECTIVES Buttonhole needling is reported to be associated with less pain than standard needling. The purpose of this study was to compare patient perceived pain and fistula complications in buttonhole and standard needling. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS In this study, 140 conventional hemodialysis patients were randomly assigned to buttonhole or standard needl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 25 1 شماره
صفحات -
تاریخ انتشار 2010