A biomechanical analysis of straight and hexagonal barbell deadlifts using submaximal loads.

نویسندگان

  • Paul A Swinton
  • Arthur Stewart
  • Ioannis Agouris
  • Justin W L Keogh
  • Ray Lloyd
چکیده

The purpose of the investigation was to compare the kinematics and kinetics of the deadlift performed with 2 distinct barbells across a range of submaximal loads. Nineteen male powerlifters performed the deadlift with a conventional straight barbell and a hexagonal barbell that allowed the lifter to stand within its frame. Subjects performed trials at maximum speed with loads of 10, 20, 30, 40, 50, 60, 70, and 80% of their predetermined 1-repetition maximum (1RM). Inverse dynamics and spatial tracking of the external resistance were used to quantify kinematic and kinetic variables. Subjects were able to lift a heavier 1RM load in the hexagonal barbell deadlift (HBD) than the straight barbell deadlift (SBD) (265 ± 41 kg vs. 245 ± 39 kg, p < 0.05). The design of the hexagonal barbell significantly altered the resistance moment at the joints analyzed (p < 0.05), resulting in lower peak moments at the lumbar spine, hip, and ankle (p < 0.05) and an increased peak moment at the knee (p < 0.05). Maximum peak power values of 4,388 ± 713 and 4,872 ± 636 W were obtained for the SBD and HBD, respectively (p < 0.05). Across the submaximal loads, significantly greater peak force, peak velocity and peak power values were produced during the HBD compared to during the SBD (p < 0.05). The results demonstrate that the choice of barbell used to perform the deadlift has a significant effect on a range of kinematic and kinetic variables. The enhanced mechanical stimulus obtained with the hexagonal barbell suggests that in general the HBD is a more effective exercise than the SBD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic and kinematic differences between deadlifts and goodmornings

BACKGROUND In order to improve training performance, as well as avoid overloading during prevention and rehabilitation exercises in patients, the aim of this study was to understand the biomechanical differences in the knee, hip and the back between the exercises "Goodmornings" (GMs) and "Deadlifts" (DLs). METHODS The kinetics and kinematics of 13 subjects, performing GMs and DLs with an addi...

متن کامل

Biomechanical Investigation of Empirical Optimal Trajectories Introduced for Snatch Weightlifting

The optimal barbell trajectory for snatch weightlifting has been achieved empirically by several researchers. They have studied the differences between the elite weightlifters’ movement patterns and suggested three optimal barbell trajectories (type A, B, and C). But they didn’t agree for introducing the best trajectory. One of the reasons is this idea that the selected criterion by researchers...

متن کامل

Complex analysis of movement in evaluation of flat bench press performance.

The complex methodology of investigations was applied to study a movement structure on bench press. We have checked the usefulness of multimodular measuring system (SMART-E, BTS company, Italy) and a special device for tracking the position of barbell (pantograph). Software Smart Analyser was used to create a database allowing chosen parameters to be compared. The results from different measuri...

متن کامل

Dynamic Analysis of the Biomechanical Model of Head Load Impact Using Differential Transform Method

The dynamic analysis of the biomechanical model of the head load impact using the Differential Transform Method is presented in this paper. In many parts of the world, the problem of traumatic brain injuries (TBI) has led to neurodegenerative dementing disorders and diseases as a result of head load impact from sporting activities, accidents involving the head, etc. have serious effects on huma...

متن کامل

Biomechanical analysis of the deadlift during the 1999 Special Olympics World Games.

PURPOSE Improper lifting techniques may increase injury risks and decrease performance. The aim of this study was to compare and contrast biomechanical parameters between sumo and conventional style deadlifts and between high- and low-skilled lifters who participated in the powerlifting event during the 1999 Special Olympics World Games. METHODS Two synchronized video cameras collected 60 Hz ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of strength and conditioning research

دوره 25 7  شماره 

صفحات  -

تاریخ انتشار 2011