Dosimetry intercomparison using a 35-keV X-ray synchrotron beam.

نویسندگان

  • Scott D Oves
  • Kenneth R Hogstrom
  • Kyungmin Ham
  • Erno Sajo
  • Joseph P Dugas
چکیده

The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field was produced by vertically oscillating a polymethylmethacrylate phantom in which dose to water was measured as a function of depth. Charge, measured using a 0.23-cm(3) cylindrical, air-equivalent ionization chamber, was converted to dose using American Association of Physicists in Medicine TG-61 protocol for 40-300 kV X-ray beam dosimetry with minor assumptions. Optical density of radiochromic film (Gafchromic EBT) was converted to dose using a 125 kVp X-ray beam (2.9 mm Al HVL) calibration curve. Fractional depth-dose curves measured using ion chamber and film agreed well with each other, the maximum difference being 4.5% at 8.85 cm. Both agreed well with that predicted by MCNP5 Monte Carlo calculations. At 2.0-cm depth, film doses from five independent measurements predicted 0.952+/-0.022 of dose measured using the ion chamber. Dose measurements using two independent methods, ionization chamber and radiochromic film dosimetry, showed good agreement and should be suitable for future dosimetry necessary for cell and small animal irradiations. Improving agreement will require additional investigations of methods for converting ionization and film optical density to dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations.

PURPOSE Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. This study performed a dosimetry intercomparison for synchrotron-produced monochromatic x-ray beams at 25 and 35 keV. Ion chamber depth-dose...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.

PURPOSE This work investigates the dose-response curves of GAFCHROMIC(®) EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. METHODS Monochromatic beams...

متن کامل

Detection of breast cancer using non-invasive X-ray diffraction technique of hair: A preliminary study

Background: An early diagnosis of breast cancer relates directly to an accurate treatment plan and strategy. Early detection of breast cancer before its development would be a significant reduction of morbidity and mortality rates. The aim of this preliminary study is to investigate the sensitivity of Wide Angle X-ray diffraction (WAXRD) method on women hair samples of healthy and breast cancer...

متن کامل

A dosimetric intercomparison of kilovoltage X-rays, megavoltage photons and electrons in the Republic of Ireland.

BACKGROUND AND PURPOSE A comprehensive dosimetry intercomparison has been carried out involving all the radiotherapy centres, all external beam modalities and every radiotherapy treatment unit in the Republic of Ireland. MATERIALS AND METHODS Reference point measurements were made for all megavoltage photon beams. Doses were also investigated in planned three-field distributions. One of these...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of radiology

دوره 68 3 Suppl  شماره 

صفحات  -

تاریخ انتشار 2008