Storage Ring Isolation Valve

نویسنده

  • J. J. SONG
چکیده

The RF impedance of the sector isolation valve of the APS storage ring system was measured by the wire method with a synthetic pulse technique [1]. The coupling impedance as well as the energy loss of the isolation valve with and without an RF liner or screen, and the flange gap of the various sizes was calculated from the measurements. There appear to be resonances at certain frequencies in the absence of an RF liner that might cause an unacceptably large coupling impedance. Data. with various sizes of the flange gap show that a good RF contact around any flange is necessary. The results also are compared with computer simulation from MAFIA. The measured impedance due to the RF liner alone is within 0.2 % of the total APS impedance budget [2].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring

The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...

متن کامل

Self-Assembled Three-Dimensional Non-Volatile Memories

The continuous increase in capacity of non-volatile data storage systems will lead to bit densities of one bit per atom by the year 2020. Beyond this point, capacity can be increased by moving into the third dimension. At the transition from two to three dimensions, we need to store data at 4·10 bit/m, or bit cell volumes of (135 nm). The transition will require the development of new manufactu...

متن کامل

Single-ring posterior left atrial (box) isolation results in a different mode of recurrence compared with wide antral pulmonary vein isolation on long-term follow-up: longer atrial fibrillation-free survival time but similar survival time free of any atrial arrhythmia.

BACKGROUND Electric isolation of the pulmonary veins and posterior left atrium with a single ring of radiofrequency lesions (single-ring isolation [SRI]) may result in fewer atrial fibrillation (AF) recurrences than wide antral pulmonary vein isolation (wide antral isolation [WAI]) by abolishing extravenous AF triggers. The effect of mitral isthmus line (MIL) ablation on outcomes after SRI has ...

متن کامل

Seismic Rehabilitation of Liquid Storage Tanks using Friction Pendulum Base Isolation subjected to the Near-Fault Ground Motions

Cylindrical liquid storage tanks are considered as vital structures in industrial complex whose nonlinear dynamic behavior is of crucial importance. Some of these structures around the world have demonstrated poor seismic behavior over the last decades. There are several methods and techniques for rehabilitation and reducing damages in these structures which among them passive control devices, ...

متن کامل

طراحی شبکه برای حلقه انبارش چشمه نور ایران

The Iranian Light Source Facility (ILSF) as a national project is a 3 GeV third generation synchrotron light source facility which provides high energy super bright X-ray for the users. Design of the ILSF storage ring emphasizes an ultra low electron beam emittance (below than 5 nm.rad), beam current of 400 mA, great brightness, stability and reliability which make it competitive in the operati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1993