Comparison of diffusion-weighted with T2-weighted imaging for detection of edema in acute myocardial infarction
نویسندگان
چکیده
BACKGROUND Recent studies, performed with the use of a commercially available diffusion weighted imaging (DWI) sequence, showed that they are sensitive to the increase of water content in the myocardium and may be used as an alternative to the standard T2-weighted sequences. The aim of this study was to compare two methods of myocardial edema imaging: DWI and T2-TIRM. METHODS The study included 91 acute and post STEMI patients. We applied a qualitative and quantitative image analysis. The qualitative analysis consisted of evaluation of the quality of blood suppression, presence of artifacts and occurrence of high signal (edema) areas. On the basis of edema detection in AMI and control (post STEMI) group, the sensitivity and specificity of TIRM and DWI were determined. Two contrast to noise ratios (CNR) were calculated: CNR1--the contrast between edema and healthy myocardium and CNR2--the contrast between edema and intraventricular blood pool. The area of edema was measured for both TIRM and DWI sequences and compared with the infarct size in LGE images. RESULTS Edema occurred more frequently in the DWI sequence. A major difference was observed in the inferior wall, where an edema-high signal was observed in 46% in T2-TIRM, whereas in the DWI sequence in 85%. An analysis of the image quality parameters showed that the use of DWI sequence allows complete blood signal suppression in the left ventricular cavity and reduces the occurrence of motion artifacts. However, it is connected with a higher incidence of magnetic susceptibility artifacts and image distortion. An analysis of the CNRs showed that CNR1 in T2-TIRM sequence depends on the infarct location and has the lowest value for the inferior wall. The area of edema measured on DWI images was significantly larger than in T2-TIRM. CONCLUSIONS DWI is a new technique for edema detection in patients with acute myocardial infarction which may be recommended for the diagnosis of acute injuries, especially in patients with slow-flow artifacts in TIRM images.
منابع مشابه
A comparision of oedema detection with diffusion-weighted imaging and T2-STIR imaging in patients with acute myocardial infarction
Background The diffusion weighted imaging (DWI) is a well known technique in neuroradiology, due to its ability to detect ischemic regions in brain tissue. A recent, rapid development of the magnetic resonance technology and echo planar imaging enabled the application of diffusion imaging in cardiac examinations. The aim of this study was to compare the diffusion weighted imaging with widely us...
متن کاملT2-Weighted Cardiac Magnetic Resonance Imaging of Edema in Myocardial Diseases
The purpose of this paper is to describe imaging techniques and findings of T2-weighted magnetic resonance imaging (MRI) of edema in myocardial diseases. T2-weighted cardiac MRI is acquired by combining acceleration techniques with motion and signal suppression techniques. The MRI findings should be interpreted based on coronary artery supply, intramural distribution, and comparison with delaye...
متن کاملBright-blood T2-weighted MRI has higher diagnostic accuracy than dark-blood short tau inversion recovery MRI for detection of acute myocardial infarction and for assessment of the ischemic area at risk and myocardial salvage.
BACKGROUND T2-Weighted MRI reveals myocardial edema and enables estimation of the ischemic area at risk and myocardial salvage in patients with acute myocardial infarction (MI). We compared the diagnostic accuracy of a new bright-blood T2-weighted with a standard black blood T2-weighted MRI in patients with acute MI. METHODS AND RESULTS A breath-hold, bright-blood T2-weighted, Acquisition for...
متن کاملCardiovascular magnetic resonance TE-averaged susceptibility weighted imaging of reperfused intramyocardial hemorrhage
Background In the setting of acute myocardial infarction (AMI), therapeutic and spontaneous reperfusion of ischemic myocardium can lead to interstitial intramyocardial hemorrhage (IMH) which is associated with microvascular obstruction (MVO) and subsequent adverse clinical outcomes. Imaging without contrast agents (native imaging) can be used in AMI patients for additional myocardial tissue cha...
متن کاملT2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.
T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE methods can be limited by artifacts such as posterior wall signal loss due to throug...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2013