Calibration curves for real-time PCR.

نویسندگان

  • K Kay-Yin Lai
  • Linda Cook
  • Elizabeth M Krantz
  • Lawrence Corey
  • Keith R Jerome
چکیده

BACKGROUND Despite the increasing use of real-time PCR in the diagnosis and management of viral infections, there are no published studies adequately addressing the optimum number of calibrators, the number of replicates of each calibrator, and the frequency with which calibration needs to be repeated. This study was designed to address these issues. METHODS Cycle threshold data (ABI 7700) was collected from >50 consecutive real-time PCR runs for hepatitis B and Epstein-Barr viruses. Our routine calibration curve made from serial 10-fold dilutions run in duplicate was compared with alternative options, including duplicate 100-fold dilutions, inclusion of a low-copy calibrator, and omission of the duplicate determination. Control data were used to examine the use of an average calibration curve made from multiple runs. RESULTS Use of duplicate serial 10-fold dilutions led to the least imprecision, duplicate 100-fold dilutions had slightly higher imprecision, and calibration curves obtained with singlet measurements showed the greatest imprecision. For patient data, the duplicate 100-fold dilution calibration curve produced results that best matched those from the routine calibration curve. Use of singlet dilutions or inclusion of a low-copy calibrator produced poorer agreement. Variability in controls was lower with a daily calibration curve than with an average calibration curve. CONCLUSIONS Duplicate 100-fold dilution calibration curves produced equivalent results and the same imprecision as curves with more calibrators, and thus are a valid alternative. Laboratories should carefully evaluate the variability resulting from the use of average calibration curves before adopting this approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PCR-based calibration curves for studies of quantitative gene expression in human monocytes: development and evaluation.

BACKGROUND Quantitative reverse transcription-PCR (RT-PCR) used to detect small changes in specific mRNA concentrations is often associated with poor reproducibility. Thus, there is a need for stringent quality control in each step of the protocol. METHODS Real-time PCR-based calibration curves for a target gene, tissue factor (TF), and a reference gene, beta-actin, generated from PCR amplico...

متن کامل

Absolute quantification of murine interleukine-4, interleukine- 10 and interferon-γ gene transcripts using Real Time PCR

The study of cytokines gene expression is quite important in various conditions of health and disease for the evaluation of clinical responses to new vaccination approaches. An absolute quantification is based on a calibration curve and production of standard controls to achieve more reliable results than in relative system. In this study we attempted to construct standard controls to evaluate ...

متن کامل

Development of SYBR Green I Based Real-Time RT-PCR Assay for Specific Detection of Watermelon silver mottle Virus

Background: Watermelon silver mottle virus (WSMoV), which belongs to the genus Tospovirus, causes significant loss in Cucurbitaceae plants. Objectives: Development of a highly sensitive and reliable detection method for WSMoV. Materials and Methods: Recombinant plasmids for targeting the sequence of nucleocapsid protein gene of WSMoV were constructed. SYBR Green I real-time PCR was established...

متن کامل

Sigmoidal curve-fitting redefines quantitative real-time PCR with the prospective of developing automated high-throughput applications.

Quantitative real-time PCR has revolutionized many aspects of genetic research, biomedical diagnostics and pathogen detection. Nevertheless, the full potential of this technology has yet to be realized, primarily due to the limitations of the threshold-based methodologies that are currently used for quantitative analysis. Prone to errors caused by variations in reaction preparation and amplific...

متن کامل

Standardisation of data from real-time quantitative PCR methods – evaluation of outliers and comparison of calibration curves

BACKGROUND As real-time quantitative PCR (RT-QPCR) is increasingly being relied upon for the enforcement of legislation and regulations dependent upon the trace detection of DNA, focus has increased on the quality issues related to the technique. Recent work has focused on the identification of factors that contribute towards significant measurement uncertainty in the real-time quantitative PCR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 51 7  شماره 

صفحات  -

تاریخ انتشار 2005