Distal femoral stem-bone anchorage of a cementless revision total hip arthroplasty

نویسندگان

  • Rüdiger J Weiss
  • Fredrik Strömwall
  • Mats O Beckman
  • Karl A Hansson
  • André Stark
چکیده

BACKGROUND AND PURPOSE According to the manual of the cementless Link MP reconstruction prosthesis, a distal femoral stem-bone anchorage of at least 80 mm is necessary to gain implant stability. There have been no in vivo studies showing that this distance is either achieved in clinical practice or needed for clinically satisfying results. Thus, we assessed the femoral stem-bone anchorage of the MP prosthesis using CT. METHODS 14 patients with the MP stem were evaluated by CT scans at a median follow-up time of 12 months postoperatively. Femoral stem-bone anchorage was defined as adequate if 50% of the stem flutes or more had cortical bone contact. The length of anchorage was derived from the number of slices with adequate anchorage. Clinical outcome was assessed with VAS for pain and Harris hip score (HHS), both at 1 and 5 years of follow-up. RESULTS The median length of stem-bone anchorage was 33 mm (interquartile range 10-60), which was shorter than recommended (p = 0.002). Still, at the 1-year control, all patients were fully weight-bearing and only 1/14 complained about mild thigh pain. 7/14 patients did not experience any pain in the affected hip. The patients had a median of 85 points in the HHS. The clinical outcome at 5 years was unchanged. INTERPRETATION We found that it can be difficult to achieve a stem-bone anchorage of at least 80 mm for the MP Link prosthesis. However, this does not appear to be necessary to obtain stability and to achieve clinically satisfying results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Proximal and Distal Femoral Canal Geometry Influences Cementless Stem Anchorage and Revision Hip and Knee Implant Stability.

Although cementless revision arthroplasty of the hip has become the gold standard, revision arthroplasty of the distal femur is controversial. This study evaluated the anchoring principles of different femoral revision stem designs in extended bone defect situations, taking into account the anatomical conditions of the proximal and distal femur, and the resulting primary stability. Cementless p...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem

BACKGROUND AND PURPOSE Due to the relative lack of reports on the medium- to long-term clinical and radiographic results of modular femoral cementless revision, we conducted this study to evaluate the medium- to long-term results of uncemented femoral stem revisions using the modular MRP-TITAN stem with distal diaphyseal fixation in a consecutive patient series. PATIENTS AND METHODS We retros...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Revision Total Hip Arthroplasty Using a Modular Cementless Distal Fixation Prosthesis: the Zmr(®) Hip System. Clinical and Radiographic Analysis of 30 Cases.

OBJECTIVE To evaluate the clinical and radiographic results from 30 cases of revision of total hip arthroplasty using a modular cementless distal fixation prosthesis: the ZMR(®) Hip System. METHOD Between July 2005 and December 2008, 30 operations were performed, on 14 men and 14 women. Two male patients had bilateral surgery. The mean age was 59.2 years (29-81 years), with a mean follow-up o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2009