Effect of LVAD outlet graft anastomosis angle on the aortic valve, wall, and flow.

نویسندگان

  • Gizem Inci
  • Esra Sorgüven
چکیده

Left ventricular assist devices (LVADs), which pump blood from the left ventricle to the aorta are an important therapy option for patients with end-stage cardiovascular diseases. Recent publications show that even with optimized LVADs fatal complications can occur because of the blood deformations around the inflow cannula or through the LVAD outlet graft-aorta anastomosis. This study investigates the effects of the anastomosis geometry on the flow through the aorta, on the pressure and wall shear stress (WSS) distributions on the aortic wall and on the total entropy generation in the anastomosis region. Anastomosis geometry is defined with two angles, one on the coronal plane and the other on the transversal plane. Turbulent flow simulations are performed for each geometry. Results indicate that 3% to 5% of the work given by the LVAD is dissipated because of the viscous losses in the anastomosis region. The entropy generation, as well as the maximum WSS, increases as the inclination angle decreases. Some portion of the blood streaming out of the LVAD conduit flows toward the aortic valve; therefore the reverse-flow region extends up to the aortic valve in some cases, which may be one of the causes of aortic-valve dysfunction. Results of this study provide insight on the importance of the anastomosis geometry on the hemodynamics in the aorta and downstream the aortic valve, stresses on the aortic wall, and viscous losses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Graft Angles Effects on the Temporal Wall Shear Stress Gradients in the Aorto-Coronary and Coronary-Coronary Bypasses

In this theoretical study, the effect of various types of bypass graft angles on the flow field, has been investigated specially on the temporal Wall Shear Stress (WSS) on the toe, heel and some locations on the bed of the Left Anterior Descending (LAD) artery at the anastomoses areas in the Aorto-Coronary (AC) and Coronary-Coronary (CC) bypasses. Flow fields in both bypasses with angles of...

متن کامل

Numerical characterization of hemodynamics conditions near aortic valve after implantation of Left Ventricular Assist Device.

Left Ventricular Assist Devices (LVADs) are implantable mechanical pumps that temporarily aid the function of the left ventricle. The use of LVADs has been associated with thrombus formation next to the aortic valve and close to the anastomosis region, especially in patients in which the native cardiac function is negligible and the aortic valve remains closed. Stagnation points and recirculati...

متن کامل

The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling.

Axial-flow ventricular assist devices (VADs) can be implanted either through a left thoracotomy with outflow-graft anastomosis to the descending thoracic aorta or through a midline sternotomy with anastomosis to the ascending aorta. Each method has advantages and disadvantages. Because these VADs produce nonpulsatile flow, their hemodynamic characteristics differ from those of pulsatile devices...

متن کامل

Left ventricular assist device outflow graft: alternative sites.

We describe three alternative approaches for the left ventricular assist device (LVAD) outflow graft during implantation of the LVAD. The supraceliac abdominal aorta, innominate artery and left axillary artery were employed as alternative sites for the LVAD outflow graft in the setting of a heavily calcified ascending aorta or a hostile chest wall and mediastinum. The first approach involved th...

متن کامل

Elevated Pressures on Aortic Valve Leaflets correlate with Orientation of LVAD Outflow Graft

Background/Introduction Better understanding of hemodynamic alterations caused by long-term use of continuous-flow left ventricular assist devices (LVAD) is necessary to evaluate their impact onto the native heart and major vessels. In particular, aortic insufficiency is a known complication after LVAD implantation and may be related to alteration of pressure distribution on the leaflets of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ASAIO journal

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 2012