A novel approach to percutaneous right-ventricular mechanical support.

نویسندگان

  • Hiroo Takayama
  • Yoshifumi Naka
  • Susheel K Kodali
  • Julie A Vincent
  • Linda J Addonizio
  • Ulrich P Jorde
  • Mathew R Williams
چکیده

OBJECTIVE We report our initial experience with our newly developed percutaneous right-ventricular assist device (VAD) with CentriMag (perc CM-RVAD). METHODS A flexible outflow cannula placed from the right internal jugular vein to the pulmonary artery and an inflow cannula placed from the femoral vein to the right atrium constituted the perc CM-RVAD. When needed, biventricular support was provided with left VAD (LVAD), either with a percutaneous LVAD placed through axillary or femoral artery access or with a fully implantable LVAD. RESULTS Between January 2009 and June 2010, all of the attempted patients successfully received perc CM-RVAD (n = 8). Mean blood pressure, heart rate, and central venous pressure showed a trend toward improvement after the perc CM-RVAD, with less inotrope/vasopressor requirement. Mixed venous oxygen saturation (SvO(2)) increased significantly from 64 ± 20 Torr to 78 ± 6 Torr (P < 0.01). The percutaneous VADs were explanted after myocardial recovery in seven patients; however, in three of these, perc CM-RVAD was used as a temporary bridge to other devices. One patient was bridged to a surgical biventricular assist device (BiVAD) and transferred back to the referring hospital on support. One death occurred due to multiple-organ failure 8 days after explantation of the RVAD with recovery. CONCLUSIONS Perc CM-RVAD was feasible and provided hemodynamic improvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Direct comparison of percutaneous circulatory support systems in specific hemodynamic conditions in a porcine model.

BACKGROUND Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. METHODS...

متن کامل

Novel multi-functional life support system.

UNLABELLED Concepts of cardiopulmonary support (CPS), extracorporeal membrane oxygenation (ECMO), and ventricular support (VS) have been thoroughly studied and refined. These perfusion adjuncts often require multiple devices, skill sets, and significant financial burden to purchase, maintain, deploy, and use. We describe a novel system that is rapidly deployable, user-friendly, portable, safe, ...

متن کامل

Temporary percutaneous right ventricular support using a centrifugal pump in patients with postoperative acute refractory right ventricular failure after left ventricular assist device implantation.

OBJECTIVE Acute right ventricular (RV) failure is a life-threatening condition with a poor prognosis, and sometimes the use of mechanical circulatory support is inevitable. In this article, we describe our experience using a centrifugal pump as a temporary percutaneous right ventricular assist device (RVAD) in patients with postoperative acute refractory RV failure after left ventricular assist...

متن کامل

Mechanical circulatory support for right ventricular failure.

OBJECTIVES The aim of this study was to explore the clinical utility of a commercially available centrifugal flow pump as a centrifugal flow-right ventricular support device (CF-RVSD) in patients with right ventricular failure (RVF). BACKGROUND RVF is associated with high in-hospital mortality. Limited data regarding efficacy of the CF-RVSD for RVF exist. METHODS We retrospectively reviewed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2012