Monitoring of Biological Changes in Electromechanical Reshaping of Cartilage Using Imaging Modalities

نویسندگان

  • Seok Jin Hong
  • Minseok Lee
  • Connie J Oh
  • Sehwan Kim
چکیده

Electromechanical reshaping (EMR) is a promising surgical technique used to reshape cartilage by direct current and mechanical deformation. It causes local stress relaxation and permanent alterations in the shape of cartilage. The major advantages of EMR are its minimally invasive nature and nonthermal electrochemical mechanism of action. The purpose of this study is to validate that EMR does not cause thermal damage and to observe structural changes in post-EMR cartilage using several imaging modalities. Three imaging modality metrics were used to validate the performance of EMR by identifying structural deformation during cartilage reshaping: infrared thermography was used to sense the temperature of the flat cartilages (16.7°C at 6 V), optical coherence tomography (OCT) was used to examine the change in the cartilage by gauging deformation in the tissue matrix during EMR, and scanning electron microscopy (SEM) was used to show that EMR-treated cartilage is irregularly arranged and the thickness of collagen fibers varies, which affects the change in shape of the cartilage. In conclusion, the three imaging modalities reveal the nonthermal and electromechanical mechanisms of EMR and demonstrate that use of an EMR device is feasible for reshaping cartilage in a minimally invasive manner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of bend angle measurements in fresh cryopreserved cartilage specimens after electromechanical reshaping

Cryopreservation of cartilage has been investigated for decades and is an established protocol. However, the reliability and application of cryopreservation of cartilage for use in electromechanical reshaping (EMR) has not been studied exclusively. A system to cryopreserve large amounts of tissue provides a steady source of similar quality cartilage for future experimentation. This will reduce ...

متن کامل

Using optical coherence tomography to monitor effects of electromechanical reshaping in septal cartilage

Electromechanical reshaping (EMR) of cartilage is a promising noninvasive technique with potential for broad application in reconstructive surgery. EMR involves applying direct current electrical fields to localized stress regions and then initiating a series of oxidation-reduction reactions, thus effecting a shape change. Previous EMR studies have focused on macroscopic structural measurements...

متن کامل

In vivo electromechanical reshaping of ear cartilage in a rabbit model: a minimally invasive approach for otoplasty.

OBJECTIVE To report the first successful study to date of in vivo electromechanical reshaping of ear cartilage in a rabbit model. METHODS Ears of New Zealand white rabbits were reshaped using percutaneous needle electrode electromechanical reshaping (5 V for 4 minutes) and were then bolstered for 4 weeks. Ten ears were treated, with 2 undergoing sham procedures and serving as controls. The tr...

متن کامل

Changes in the tangent modulus of rabbit septal and auricular cartilage following electromechanical reshaping.

Transforming decades' old methodology, electromechanical reshaping (EMR) may someday replace traditionally destructive surgical techniques with a less invasive means of cartilage reshaping for reconstructive and esthetic facial surgery. Electromechanical reshaping is essentially accomplished through the application of voltage to a mechanically deformed cartilage specimen. While the capacity of ...

متن کامل

Electromechanical reshaping of ex vivo porcine trachea.

OBJECTIVES The trachea is a composite cartilaginous structure particularly prone to various forms of convexities. Electromechanical reshaping (EMR) is an emerging technique used to reshape cartilaginous tissues by applying electric current in tandem with imposed mechanical deformation to achieve shape change. In this study, EMR was used to reshape tracheal cartilage rings to demonstrate the fea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016