Evaluation of Two New Electronic Apex-Locator-Controlled Handpieces Using a NiTi Rotary File: An In Vitro Study

نویسندگان

  • Kiumarz Nazarimoghadam
  • Hossein Labaf
چکیده

OBJECTIVES The aim of this in-vitro study was to compare the accuracy of two new electronic apex-locator controlled handpieces (EALHs) using the first rotary Mtwo file while rotating in the canal. MATERIALS AND METHODS A total of 36 extracted mandibular molar teeth were selected. The lengths of the mesio-buccal canals to the major foramina were measured directly using a size 10 K-file introduced in the canal until the tip was visible under a loupe and then 0.5 mm was subtracted from the recorded lengths as the actual working lengths (AWLs). Subsequently, the teeth were randomly assigned to two groups and embedded in an alginate model. Auto-stop function of the EALHs was preset at "0.5" mark and then electrical working lengths (EWLs) in groups 1 and 2 were recorded by VDW GOLD and Dentaport ZX, respectively. Analysis of variance (ANOVA, 1-way) and Tukey pairwise multiple comparison intervals (0.05) were used to compare the accuracy of the two electronic devices. RESULTS For VDW GOLD, 61.1% of the measurements were within ±0.5 mm and 88.9% were within ±1 mm of the AWL. For Dentaport ZX, 88.9% of the measurements were within ±0.5 mm and 94.4% were within ±1mm of the AWL. There was no significant difference between AWLs and EWLs (p=0.466 for Dentaport ZX and p=0.283 for VDW Gold) and between the accuracy of the two devices in determining the EWL (p=0.8). CONCLUSION Both Dentaport ZX and VDW Gold were suitable for determining working length using a rotary file. To avoid over instrumenting the canal, we recommend setting the devices to automatically stop or reverse the rotary file at 1 mm level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file.

OBJECTIVES Today many clinicians use both stainless-steel hand K-files and nickel- titanium rotary files during endodontic treatment. It is of great importance for the clinician to have confidence in the accuracy of an apex locator even if these files were used interchangeably. The purpose of this in vitro study was to evaluate the accuracy of the Raypex5 electronic apex locator using stainless...

متن کامل

An in vivo comparison of the Root ZX II, the Apex NRG XFR, and Mini Apex Locator by using rotary nickel-titanium files.

INTRODUCTION The purpose of this study was to compare the accuracy of working length (WL) measurements by using the Root ZX II, Apex NRG XFR, and Mini Apex Locator with rotary nickel-titanium (NiTi) instruments. METHODS Twenty-eight teeth had their WLs determined with each electronic apex locator (EAL) by using 0.04 taper ProFiles sizes 40-20 in a crown-down technique until WL was reached. Fo...

متن کامل

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

Accuracy of electronic apex locater-controlled handpieces.

An in vitro model was used to test a hypothesis that the manual (apex locator) and motor-driven (apex locator-controlled handpiece) operating modes of 3 newly developed apex-locator-controlled handpiece devices (Dentaport ZX, Endomaster, XSmart Dual) give the same working length. The depth of penetration of the file into the root canal was measured using a digital micrometer and the distance of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2013