Nanoparticle PET-CT detects rejection and immunomodulation in cardiac allografts.

نویسندگان

  • Takuya Ueno
  • Partha Dutta
  • Edmund Keliher
  • Florian Leuschner
  • Maulik Majmudar
  • Brett Marinelli
  • Yoshiko Iwamoto
  • Jose-Luiz Figueiredo
  • Thomas Christen
  • Filip K Swirski
  • Peter Libby
  • Ralph Weissleder
  • Matthias Nahrendorf
چکیده

BACKGROUND Macrophages predominate among the inflammatory cells in rejecting allografts. These innate immune cells, in addition to allospecific T cells, can damage cardiomyocytes directly. METHODS AND RESULTS We explored whether sensitive positron emission tomography-computed tomography (PET-CT) imaging of macrophages-avid nanoparticles detects rejection of heart allografts in mice. In addition, we used the imaging method to follow the immunomodulatory impact of angiotensin-converting enzyme inhibitor therapy on myeloid cells in allografts. Dextran nanoparticles were derivatized with the PET isotope copper-64 and imaged 7 days after transplantation. C57BL/6 recipients of BALB/c allografts displayed robust positron emission tomography signal (standard uptake value allograft, 2.8±0.3; isograft control, 1.7±0.2; P<0.05). Autoradiography and scintillation counting confirmed the in vivo findings. We then imaged the effects of angiotensin-converting enzyme inhibitor (5 mg/kg enalapril). Angiotensin-converting enzyme inhibitor significantly decreased nanoparticle signal (P<0.05). Histology and flow cytometry showed a reduced number of myeloid cells in the graft, blood, and lymph nodes and diminished antigen presentation (P<0.05 versus untreated allografts). Angiotensin-converting enzyme inhibitor also significantly prolonged allograft survival (12 versus 7 days; P<0.0001). CONCLUSIONS Nanoparticle macrophage PET-CT detects heart transplant rejection and predicts organ survival by reporting on myeloid cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pericardial sarcoidosis presenting as PUO diagnosed on FDG PET CT scan

Pyrexia of unknown origin (PUO) is a common problem in day-to-day practice. FDG PET CT is an established investigation that aids in identifying the cause of PUO. Due to its high sensitivity PET detects an occult hypermetabolic focus in the body where CT helps in anatomical localization, vascularity, enhancement characteristics of the lesion detected on PET. It helps to differentiate benign vers...

متن کامل

Rare case of squamous cell carcinoma of buccal mucosa metastasizing to interventricular septum in a young adult detected by 18F-FDG PET-CT

Metastatic tumors to the heart unlike primary cardiac tumors are not rare. Despite its frequency, cardiac metastasis is commonly detected only during autopsy as the symptoms of disseminated metastasis prevail over symptoms caused by cardiac metastasis and hence is overlooked most of the time. Tumors more commonly found metastasizing to the heart are malignancies of lung, breast, esophagus, lymp...

متن کامل

[18F]FDG PET/CT in a case of recurrent primary cardiac osteosarcoma

Primary cardiac osteosarcoma is a very rare malignancy with a high incidence of local recurrence and systemic metastasis, contributing to the poor prognosis. Radiological modalities are commonly used for the evaluation of cardiac masses. 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography/computed tomography is a valuable whole-body imaging modality in ...

متن کامل

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2013