BACKGROUND Intrathoracic impedance-derived OptiVol fluid index calculated using implanted devices has been shown to predict mortality; direct measurements of impedance have not been examined. We hypothesized that baseline measured impedance predicts all-cause mortality; changes in measured impedance result in a change in the predicted mortality; and the prognostic value of measured impedance is additive to the calculated OptiVol fluid index. METHODS AND RESULTS A retrospective analysis of 146,238 patients within the Medtronic CareLink database with implanted devices was performed. Baseline measured impedance was determined using daily values averaged from month 6 to 9 after implant and were used to divide patients into tertiles: group L = low impedance, ≤ 65 ohms; group M = medium impedance, 66 to 72 ohms; group H = high impedance, ≥ 73 ohms. Change in measured impedance was determined from values averaged from month 9 to 12 post implant compared with the 6- to 9-month values. OptiVol fluid index was calculated using published methods. All-cause mortality was assessed beginning 9 months post implant; changes in mortality was assessed beginning 12 months post implant. Baseline measured impedance predicted all-cause mortality; 5-year mortality for group L was 41%, M was 29%, and H was 25%, P < 0.001 among all groups. Changes in measured impedance resulted in a change in the predicted mortality; the prognostic value of measured impedance was additive to the OptiVol fluid index. CONCLUSIONS Direct measurements of intrathoracic impedance using an implanted device can be used to stratify patients at varying mortality risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Descending Aortic Flow Contribution to Intrathoracic Impedance—development and Preliminary Testing of a Dual Impedance Model

Objective. Impedance measurement of cardiac output has struggled to become established partly because there have been only a few attempts to establish a sound theoretical basis for this measurement. Our objective is to demonstrate that there is valuable aortic flow information available from an intrathoracic impedance signal which may eventually be useful in the measurement of cardiac output by...

متن کامل

Threshold crossing of device-based intrathoracic impedance trends identifies relatively increased mortality risk

AIMS Threshold crossings of impedance trends detected by implanted devices have been associated with clinically relevant heart failure events, but long-term prognosis of such events has not been demonstrated. The aim of this study is to examine the relationship between alterations in intrathoracic impedance and mortality risk in patients with implantable devices. METHODS AND RESULTS We review...

متن کامل

Modified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation

In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...

متن کامل

Hyperglycemia and Red Cell Distribution Width for Prediction of Mortality in Preschool Children with Community Acquired Pneumonia (CAP)

Background Community acquired pneumonia (CAP) is a major infectious cause of mortality in preschool children especially in developing countries. Red Cell Distribution Width (RDW) has been associated with poor outcomes of CAP. We aimed to determine whether admission stress hyperglycemia and RDW can predict mortality in preschool children with CAP for early identification of patients at risk of ...

متن کامل

Nyquist Plots Prediction Using Neural Networks in Corrosion Inhibition of Steel by Schiff Base

The corrosion inhibition effect of N,N′-bis(n-Hydroxybenzaldehyde)-1,3-Propandiimine on mild steel has been investigated in 1 M HCl using electrochemical impedance spectroscopy. A predictive model was presented for Nyquist plots using an artificial neural network. The proposed model predicted the imaginary impedance based on the real part of the impedance as a function of time. The model to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2016