Low levels of 1,5-anhydro-D-glucitol are associated with vascular endothelial dysfunction in type 2 diabetes

نویسندگان

  • Keiichi Torimoto
  • Yosuke Okada
  • Hiroko Mori
  • Yoshiya Tanaka
چکیده

BACKGROUND Vascular endothelial dysfunction is involved in macrovascular disease progression in type 2 diabetes mellitus (T2DM). We reported previously that blood glucose fluctuations, as evaluated by continuous glucose monitoring (CGM), correlate with vascular endothelial function, serving as a marker of vascular endothelial function. However, the use of CGM is limited, suggesting the need for another marker of vascular endothelial function. Here, we investigated the relationship between vascular endothelial dysfunction and blood levels of 1,5-anhydro-D-glucitol (1,5-AG), a marker of both postprandial hyperglycemia and fluctuations in blood glucose. METHODS In 32 inpatients with T2DM and HbA1c less than 8.0%, the reactive hyperemia index (RHI), an index of vascular endothelial function, was determined by peripheral arterial tonometry. The relationships between RHI and 1,5-AG, blood glucose, lipid metabolism markers, and blood pressure, were examined. RESULTS There was a strong correlation between 1,5-AG and natural logarithmic-scaled RHI (L_RHI) (r = 0.55; P = 0.001). However, there was no correlation between L_RHI and HbA1c, fasting blood glucose, IRI, LDL-C, HDL-C, TG, systolic blood pressure, or diastolic blood pressure. Multivariate analysis identified blood 1,5-AG levels to be the only significant and independent determinant of L_RHI. CONCLUSIONS In T2DM with HbA1c <8.0%, low 1,5-AG levels were associated with vascular endothelial dysfunction, suggesting it is a potentially useful marker for vascular endothelial dysfunction. TRIAL REGISTRATION UMIN000015317.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

1,5-Anhydro-D-Glucitol Could Reflect Hypoglycemia Risk in Patients with Type 2 Diabetes Receiving Insulin Therapy

BACKGROUND The identification of a marker for hypoglycemia could help patients achieve strict glucose control with a lower risk of hypoglycemia. 1,5-Anhydro-D-glucitol (1,5-AG) reflects postprandial hyperglycemia in patients with well-controlled diabetes, which contributes to glycemic variability. Because glycemic variability is related to hypoglycemia, we aimed to evaluate the value of 1,5-AG ...

متن کامل

Simple enzymatic method for determining 1,5-anhydro-D-glucitol in plasma for diagnosis of diabetes mellitus.

We have developed a simple method for determination of 1,5-anhydro-D-glucitol in plasma, based on use of pyranose oxidase (EC 1.1.3.10), an enzyme with specificity toward pyranoid compounds such as 1,5-anhydro-D-glucitol and glucose. Plasma samples deproteinized with trichloroacetic acid are passed through a two-layer mini-column packed with strongly basic anion (OH- form, the upper layer) and ...

متن کامل

The Application of Plasma 1,5-Anhydro-D-glucitol for Monitoring Type 2 Diabetic Patients

AIM Recent data have suggested that effective control of postprandial blood glucose can reduce the risk of macroangiopathic complications of diabetes, especially cardiovascular risk. 1,5-Anhydro-D-glucitol (1,5-AG) has been proposed as a marker of short-term hyperglycaemic excursions. We aimed to evaluate its usefulness in patients with type 2 diabetes and have attempted to indicate when 1,5-AG...

متن کامل

Fully automated flow-injection system for quantifying 1,5-anhydro-D-glucitol in serum.

We have developed a flow-injection system with colorimetric detection to measure 1,5-anhydro-D-glucitol in serum. Serum samples are directly and serially injected into a clean-up column every 3.5 min to remove interferences before the enzymatic reaction. 1,5-Anhydro-D-glucitol, after being passed through the column, is oxidized by immobilized pyranose oxidase (EC 1.1.3.10), and the hydrogen per...

متن کامل

Plasma 1,5-anhydro-D-glucitol concentration and its relation to other plasma components in renal failure and renal transplant recipients.

Plasma levels of 1,5-anhydro-D-glucitol (AG) were measured in non-diabetic patients with renal failure or following renal transplant. For patients with renal failure (n = 20) from various causes, the plasma level of AG was found to be positively associated with urate and negatively with both urea and prior dialysis. The results for seven renal transplant recipients, serially assessed during the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014