Current Conveyor Based Wide-band Current Driver for Electrical Impedance Tomography

نویسنده

  • Arun Rao
چکیده

Electrical Impedance Tomography (EIT) for prostate and breast cancer detection require wide-band ac current drivers which can deliver current up to 10MHz. The current drivers should exhibit low harmonic distortion and provide accurate current to the tissue being examined. This work presents an integrated current driver which can deliver 1.2mA of current up to frequencies of 10MHz. The current source was fabricated in CMOS 0.18-μm technology with a power supply of 3.3V, and occupies a core area of 0.26mm. The measured harmonic distortion for a peak current of 1.2mA is < 0.1% for frequencies less than 100kHz, and increases to 0.68% at 10MHz. The output impedance measured is 101kΩ at 1MHz and 19.5kΩ at 10MHz. The circuit is suitable for high frequency small form factor EIT systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Approach for Low Voltage CMOS based on Current-controlled Conveyors

Abstract  In his paper a new current-controlled conveyor (CCCII) in CMOS technology is presented. It features, low supply voltage (±0.7), low power consumption, low circuit complexity, rail to rail operation and wide range parasitic resistance ( ). The circuit has been successfully employed in a multifunction biquad filter. Simulation results by HSPICE show high performance of the circuit and c...

متن کامل

Performance of the Load-in-the-Loop Single Op-Amp Voltage Controlled Current Source from the Op-Amp Parameters

In recent years, Electrical Bioimpedance (EBI) methods have gained importance. These methods are often based on obtaining impedance spectrum in the range of β-dispersion, i.e. from a few kHz up to some MHz. To measure EBI a constant current is often injected and the voltage across the tissue under study is recorded. Due to the performance of the current source influences the performance of the ...

متن کامل

Asymmetrical-fed RHCP Wide-Band Slot Element for X-Band applications

An outstanding square slot element, for x-band wireless applications with asymmetric coplanar waveguide fed (CPW) is proposed. Various shapes of metallic strips are utilized as grounded stubs for providing Right Hand Circular Polarization (RHCP) functionality and wide-band properties. By adjusting the proposed stubs and hook-shaped radiator, length and positions, wider impedance band width is o...

متن کامل

New low-voltage class AB current conveyor II for analog applications

Current conveyors are unity gain active elements exhibiting high linearity, wide dynamic range and high frequency performance than their voltage mode counterparts. The new current conveyor operating at low-voltage supplies high input impedance and low output impedance and consumes less power. In this study, a new low-voltage class AB second generation current conveyor (AB CCII) is presented whi...

متن کامل

On dynamic range limitations of CMOS current conveyors

This paper is concerned with the dynamic range of continuous time CMOS current mode circuits. As a representative current mode device a class AB current conveyor is examined. First, the voltage input range of the high impedance Y input is investigated. Next, the current input range of the low impedance X input is investigated. It is compared to the thermal noise in the X to Z signal path in ord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017