Characterizing Mammalian cells and cell phantoms by polarized backscattering fiber-optic measurements.
نویسندگان
چکیده
Fiber-optic, polarized elastic-scattering spectroscopy techniques are implemented and demonstrated as a method for determining both scatterer size and concentration in highly scattering media. Measurements of polystyrene spheres are presented to validate the technique. Measurements of biological cells provide an estimate of the average effective scatterer radius of 0.5-1.0 mum. This average effective scatterer size is significantly smaller than the nucleus. In addition, to facilitate use of polarization techniques on biological cells, polarized angular dependent scattering from cell suspensions was measured. The light scattering from cells has properties similar to those of small spheres.
منابع مشابه
A fiber optic probe design to measure depth-limited optical properties in-vivo with low-coherence enhanced backscattering (LEBS) spectroscopy.
Low-coherence enhanced backscattering (LEBS) spectroscopy is an angular resolved backscattering technique that is sensitive to sub-diffusion light transport length scales in which information about scattering phase function is preserved. Our group has shown the ability to measure the spatial backscattering impulse response function along with depth-selective optical properties in tissue ex-vivo...
متن کاملMeasurement of intrinsic optical backscattering characteristics of cells using fiber-guided near infrared light
BACKGROUND Intrinsic optical signals (IOS), which reflect changes in transmittance and scattering light, have been applied to characterize the physiological conditions of target biological tissues. Backscattering approaches allow mounting of the source and detector on the same side of a sample which creates a more compact physical layout of device. This study presents a compact backscattering d...
متن کاملFiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)
The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...
متن کاملخواص نوری- مغناطیسی و ضرایب اپتیکی لایههای نازک منگنز-کبالت
Having precise hysterics loop of thin ferroelectric and ferromagnetic layers for optical switching and optical storages are important. A hysterieses loop can be achieved from a phenomenon call the magneto-optic effect. The magneto-optic effect is the rotation of a linear polarized electromagnetic wave propagated through a ferromagnetic medium. When light is transmitted through a layer of magnet...
متن کاملEffect of Two Polarized Culture System Prepared From Human Female Genital Tract on Mouse Embryo Development
Purpose: To compare effects of polarized epithelial monolayer prepared from human oviduct and uterus on mouse one and two-cell embryo development. Materials and Methods: Human oviduct and endometrial tissue was obtained from patients who had undergone total hysterectomy. The epithelial cells were isolated from tissue and cultured on extracellular matrix (ECM) Gel coated Millipore filter insert...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 40 28 شماره
صفحات -
تاریخ انتشار 2001