Oxygen tension under a contact lens.

نویسندگان

  • K A Polse
  • M Decker
چکیده

Corneal thickness changes were measured on human subjects who wore gel lenses that varied in center thickness. Using these measurements and the results of an earlier study in which changes in corneal thickness were monitored on human corneas exposed to oxygen tensions below that in air, we showed that the oxygen tension under most contact lenses varies from 0 to 25 mm Hg which produces a corresponding oxygen flux into the cornea of 0 to 6 microliter cm2 hr. A critical oxygen tension and flux under the lens was found to be 10 mm Hg and 2 microliter cm2 hr, respectively, below which corneal swelling occurs. To maintain these critical levels of tension and flux, the minimum oxygen transmissibility of a stationary lens on the cornea was determined to be 5 X 10(-9) and 15 X 10(-9) (cm X ml O2)/(sec X ml X mm Hg) for the open and closed eye conditions, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Critical Contact Lens Oxygen Transmissibility and Tear Lens Oxygen Tension to Preclude Corneal Neovascularization.

OBJECTIVE The purpose of this study is to determine the peripheral oxygen transmissibility (pDk/t) and respective central oxygen transmissibility (cDk/t) in soft contact lenses (SCLs) which might preclude SCL-driven corneal neovascularization (NV) in healthy myopic SCL users. METHODS Twenty subjectively successful SCL-wearing patients who presented with asymptomatic but active peripheral corn...

متن کامل

Oxygen tension in the anterior chamber of the rabbit eye.

The oxygen tension in the aqueous humor in the anterior chamber of rabbit eyes was measured continuously with a polarographic electrode. The normal oxygen tension in the anterior chamber was 23 +/- 2 mm Hg (mean +/- SD, n = 4). A contact lens was then placed on the cornea for at least 10 min and the drop in oxygen tension recorded. A hard polymethylmethacrylate lens reduced the oxygen tension b...

متن کامل

Direct noninvasive measurement of tear oxygen tension beneath gas-permeable contact lenses in rabbits.

PURPOSE To develop a noninvasive measurement of tear oxygen tension and to determine tear oxygen tension and calculated oxygen flux rates during wear of contact lenses of varying oxygen transmissibility (Dk/L). METHODS The basis of the tear oxygen tension (PO2) measurement is phosphorescence quenching of Pd-meso-tetra-(4-carboxyphenyl) porphine by oxygen. A fiber-optic bundle, positioned appr...

متن کامل

Polarography: an oxygen survey correlating oxygen transmissibility to "EOP" values.

A polarographic oxygen electrode was used to measure the oxygen transmissibility of seven contact lenses of varying water content and center thickness. A similar electrode was used to measure the oxygen uptake following wear of these same contact lenses for both the open- and closed-eyelid conditions on five young healthy subjects. Linear regression revealed a strong correlation between oxygen ...

متن کامل

Effect of long-term contact lens wear on corneal endothelial cell morphology and function.

Anterior segment fluorophotometry (topical) and central endothelial cell photography were performed on 40 long-term (2-23 years) contact lens wearers (four groups of ten each: hard, soft, gas permeable, and gas permeable plus prior lens usage) and 40 non-contact lens wearers of similar ages. Morphologically, the endothelial cells of contact lens wearers showed greater variability in size and sh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 1979