Automated Registration of Sequential Breath-Hold DCE-MRI Images

نویسندگان

  • S. Rajaraman
  • J. J. Rodriguez
  • C. Graff
  • M. I. Altbach
  • T. Dragovich
  • C. B. Sirlin
  • R. L. Korn
  • N. Raghunand
چکیده

S. Rajaraman, J. J. Rodriguez, C. Graff, M. I. Altbach, T. Dragovich, C. B. Sirlin, R. L. Korn, and N. Raghunand Electrical & Computer Engineering, The University of Arizona, Tucson, AZ, United States, Radiology, The University of Arizona, Tucson, AZ, United States, Cancer Center, The University of Arizona, Tucson, AZ, United States, Radiology, The University of California, San Diego, CA, United States, Scottsdale Medical Imaging Ltd., Scottsdale, AZ, United States

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of image registration on pharmacokinetic parameter extraction using 3D DCE-MRI

Introduction: Residual patient motion between images in breath-hold DCE-MRI may compromise image analysis such as the extraction of pharmacokinetic parameters. This work analyses results of the Progressive Principal Component Registration (PPCR) algorithm [1] on six 3D DCE-MRI datasets. These datasets are acquired at a temporal resolution of 12s consisting of a 6s breath-hold volume acquisition...

متن کامل

Free-Breath DCE MRI for Solitary Pulmonary Nodule with Motion Correction Based on Non-Rigid Image Registration

Introduction Dynamic contrast-enhanced (DCE) MRI has proven valuable to characterize tissue of interest in solitary pulmonary nodule (SPN) [1], especially for delineating malignant from benign tumor. In DCE MRI studies, the kinetics of signal variation at lesions following the administration of the contrast agent is analyzed from time-intensity curve. Thus, it is crucial to measure the signal i...

متن کامل

Validation of Registration for Renal Dynamic Contrast Enhanced MRI Imaging

In Dynamic Contrast Enhanced Resonance Imaging (DCE-MRI), abdomen is scanned repeatedly and rapidly after injection of a contrast agent. During data acquisition, collected images suffer from the motion induced by the patient if he/she moves or breathes heavily during the scan. Therefore, these images should be aligned accurately to correct the motion. Recently, mutual information (MI) registrat...

متن کامل

Motion compensated reconstruction for free breathing dynamic constrast-enhanced MRI

INTRODUCTION: In contrast-enhanced MRI, medical diagnosis is often compromised by the motion, the need for registration and the difficulty of sustaining a breath-hold. A previously published motion correction algorithm GRICS (Generalized Reconstruction by Inversion of Coupled Systems) [1] has proven to correct for motion artefacts successfully in images acquired with a wide set of sequences, th...

متن کامل

Assessment of pulmonary perfusion with breath-hold and free-breathing dynamic contrast-enhanced magnetic resonance imaging: quantification and reproducibility.

OBJECTIVES The purpose of this study was to investigate whether quantification of pulmonary perfusion from dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) yields more reproducible results with data acquired during free breathing than with data from conventional breath-hold measurements. MATERIAL AND METHODS Ten healthy male volunteers underwent 2 imaging sessions at a clinical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008