Lymphoscintigraphy and sentinel node localization in breast cancer patients: a comparison between 1-day and 2-day protocols.

نویسندگان

  • H W Yeung
  • H S Cody III
  • A Turlakow
  • E R Riedel
  • J Fey
  • M Gonen
  • R Nuñez
  • S D Yeh
  • S M Larson
چکیده

UNLABELLED The purpose of this study was to compare the results of isotope injection the morning of surgery (1-d protocol) with isotope injection the day before surgery (2-d protocol) in patients having sentinel lymph node (SLN) biopsy for breast cancer. METHODS The 1-d (protocol 1) and 2-d (protocol 2) protocols included 514 and 152 patients, respectively, treated contemporaneously by surgeons experienced with the SLN biopsy technique. All had preoperative lymphoscintigraphy (LSG) and SLN biopsy using both blue dye and (99m)Tc-sulfur colloid. All patients had a single-site intradermal injection of unfiltered (99m)Tc-sulfur colloid in 0.05 mL normal saline: 3.7 MBq (0.1 mCi) on the morning of surgery for protocol 1 and 18.5 MBq (0.5 mCi) on the afternoon before surgery for protocol 2. RESULTS The patients in protocols 1 and 2 were comparable in terms of age, tumor size, tumor location, histologic type, node positivity, and frequency of a previous surgical biopsy. Comparing protocols 1 and 2, early (30 min) LSG images found the SLN equally often (69% vs. 68%). Isotope identified the SLN equally often at surgery (93% vs. 97%) as did isotope plus dye (98% vs. 99%). A comparable number of SLNs was found (2.5 vs. 2.8 per axilla), and the concordance between isotope and dye in the SLN was also comparable (97% vs. 95%). Late LSG images (at 2 h, possible only for protocol 2) identified the SLN in significantly more patients compared with early images (86% vs. 68%). CONCLUSION With unfiltered (99m)Tc-sulfur colloid injected intradermally, the results of SLN biopsy under the 1-d and 2-d protocols are virtually identical. A 2-d protocol allows increased efficiency in scheduling, both for nuclear medicine physicians and for the operating room, with no compromise in the effectiveness of SLN mapping.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients

Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...

متن کامل

Dynamic lymphoscintigraphy in breast cancer patients: feasibility and added value

Introduction: Lymphoscintigraphy is imaging of the lymphatic system and has been integrated into the sentinel node mapping procedures. Lymphoscintigraphy usually encompasses early or delayed static images. However, immediate dynamic imaging of the lymphatic basins and tumors has also been used as an adjunct lymphoscintigraphy imaging. The aim of this study was ...

متن کامل

Time frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information

Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...

متن کامل

An Ultralow-Dose 1-Day Protocol With Activities Lower Than 20 MBq for the Detection of Sentinel Lymph Nodes in Breast Cancer—Experiences After 150 Cases

INTRODUCTION Common protocols for the detection of sentinel lymph nodes in early breast cancer often include the injection of the tracer 1 day before surgery. In order to detect enough activity on the day of surgery, the applied activity in many protocols is as high as several hundred MBq. So far, very few protocols with an activity below 20 MBq have been reported. We developed an ultralow-dose...

متن کامل

Radiotracer re-injection in case of sentinel node non-visualization in a breast cancer patient

We reported a 35 year old breast cancer patient who was referred to our nuclear medicine department for sentinel node mapping. She was planned to undergo mastectomy and lymphatic mapping. A dose of Tc-99m Phytate was injection in the peri-areolar region in an intra-dermal fashion. Two hours post-injection no sentinel node was visible in the axilla. Due to a high liver uptake, inadvertent intra-...

متن کامل

Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid

  Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2001