Inappropriate shocks by subcutaneous implantable cardioverter-defibrillator due to T-wave oversensing in hyperkalemia leading to ventricular fibrillation
نویسندگان
چکیده
Introduction The implantable cardioverter-defibrillator (ICD) has reduced mortality in survivors of sudden cardiac arrest and patients at high risk of sudden cardiac death. This benefit comes at the cost of device-related complications, including those related to transvenous leads. The subcutaneous ICD (S-ICD) is an alternative to the conventional transvenous ICD (TV-ICD) system and has no transvenous leads, thereby avoiding endocardial lead–related complications. However, with only subcutaneous electrodes, rhythm detection and discrimination is a much more challenging task for the S-ICD. We describe a case of ventricular fibrillation induced by inappropriate shocks from the S-ICD owing to T-wave oversensing (TWOS) in the setting of hyperkalemia and dialysisdependent chronic renal failure.
منابع مشابه
Inappropriate shocks from a subcutaneous implantable cardioverter-defibrillator due to oversensing during periods of rate-related bundle branch block
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a novel technology with proven efficacy in sudden cardiac death prevention; however, there is a lack of long-term safety data. We describe the case of a 55-year-old female patient implanted with an S-ICD due to idiopathic ventricular fibrillation, who subsequently presented with inappropriate shocks leading to ventricular fibril...
متن کاملA case of inappropriate implantable cardioverter defibrillator therapy induced by T-wave oversensing due to hyperkalemia.
There have been reports of hyperkalemia-induced T-wave oversensing in patients with implantable cardioverter defibrillators (ICDs). However, a comparison of T-wave amplitudes and morphologies between the surface 12-lead electrocardiogram (ECG) and ICD electrogram has not been reported. We present the case of a 70-year-old man who received inappropriate ICD shocks due to hyperkalemia-induced T-w...
متن کاملOversensing of atrial fibrillatory waves in a subcutaneous implantable cardioverter-defibrillator
Introduction Implantable cardioverter-defibrillators (ICDs) have been shown to improve survival in patients with ischemic or nonischemic cardiomyopathy when used for primary and secondary prevention settings. The limitations of transvenous ICDs include postimplant adverse events, defibrillator lead failure, and inappropriate shocks for atrial tachyarrhythmias due to fast ventricular response ra...
متن کاملHyperglycemia-Induced T-Wave Oversensing as a Cause of Cardiac Resynchronization Therapy (CRT) Failure
T-wave oversensing occurs when the counter starts giving dual beeps for every cardiac cycle instead of one. This usually happens when the monitoring lead displays a tall T wave, which is also sharp. R wave sensing algorithms of the devices do not sense T wave because the slow rate of the T wave is much less than that of the R wave. But the slow rate of T waves may change with time and also beca...
متن کاملDownloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
BACKGROUND The primary method for monitoring implantable cardioverter-defibrillator lead integrity is periodic measurement of impedance. Sprint Fidelis leads are prone to pace-sense lead fractures, which commonly present as inappropriate shocks caused by oversensing. METHODS AND RESULTS We developed and tested an algorithm to enhance early identification of lead fractures and to reduce inappr...
متن کامل