Plasma glucose concentrations of whole blood, as determined with a multilayer-film analytical element.

نویسندگان

  • A Ohkubo
  • S Kamei
  • M Yamanaka
  • F Arai
  • M Kitajima
  • A Kondo
چکیده

A new type of multilayer film analytical element--consisting of a spreading layer, a blocking layer, an enzymic reagent layer, and a transparent layer--has been developed for blood glucose determination. After a spot of whole blood is dropped on the film, the plasma glucose concentration is determined in 6 min without further manipulations. Precise measurement of sample volume spotted on the film is not necessary for good results, nor is knowledge of the hematocrit in the range 10-46%. The minimum concentration of glucose detectable by this method is 100 mg/L. The coefficients of variation, within-run and between-run, were all less than 2.5% for 800-4000 mg/L glucose concentrations. Macromolecules and hydrophobic substances in blood did not interfere. This method seems suitable for emergency use, especially.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multilayer-film analysis for urea nitrogen in blood, serum, or plasma.

Two types of multilayer-film slides for measurement of urea nitrogen in blood are reported here: one for whole-blood samples, the other for plasma or serum. Urea nitrogen concentrations in plasma are determined almost immediately, without preparation of reagents or centrifugation of blood samples. Because the sample volume applied to the slide is not critical, reliable results are quickly obtai...

متن کامل

A multilayer element for determining hemoglobin in whole blood: principles and analytical performance.

We described the structure and analytical performance of a thin-film element for determining total hemoglobin in whole blood. The element can be used with the Kodak Ektachem DT60 analyzer. The method, analogous to the standard Drabkin's method, provides accurate and precise results on 10-microL samples of undiluted whole blood. Dynamic range is linear from 0 to 200 g/L, and the method is relati...

متن کامل

Rate of Glucose Utilization by Blood Cells in Serum and Plasma Specimens With or Without Using Preservative

Objective: This study aims to estimate and compare the time-course change in blood glucose levels by blood cells in serum, and plasma with or without preservatives, which may reflect the rate of glucose utilization by blood cells. Method: This laboratory-based cross-sectional study was carried out using a blood specimen of 28 participants among which 14 were diagnosed with diabetes and 14 were...

متن کامل

A Review on Titanium Nitride and Titanium Carbide Single and Multilayer Coatings Deposited by Plasma Assisted Chemical Vapor Deposition

In this paper, we reviewed researches about the titanium nitride (TiN) and titanium carbide (TiC) single and multilayer coatings. These coatings were deposited by the plasma assisted chemical vapor deposition (PACVD) technique. Plasma-based technologies are used for the processing of thin films and coatings for different applications such as automobile and aerospace parts, computer disc drives,...

متن کامل

COMPARISON OF PROPERTIES OF TiN/TiCN AND PLASMA NITRIDING/TiCN FILMS DEPOSITED ON THE TOOL STEEL BY PULSED DC- PACVD

In this work, TiN/TiCN & PN/TiCN multilayer films were deposited by plasma- assisted chemical vapour deposition (PACVD). Plasma nitriding (PN) and TiN intermediate layer prior to coating leads to appropriate hardness gradient and it can greatly improve the mechanical properties of the coating. The composition, crystalline structure and phase of the films were investigated by X-ray d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 7  شماره 

صفحات  -

تاریخ انتشار 1981