A dummy cell for differential-pulse polarographic analysers.

نویسندگان

  • H Guterman
  • S Ben-Yaakov
چکیده

A non-linear network is proposed for simulating the response of electrochemical cells in differential-pulse polarographic (DPP) analysis. The response of a DPP analyser connected to the dummy cell is a bell-shaped current peak (I(p)) located at any desired point along the potential-scan range. Approximate model calculations of the expected I(p), as a function of the dummy-cell parameters are in good agreement with measured data. It is suggested that the dummy cell could be useful in the analytical laboratory and during studies for improving DPP analysers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential Pulse Polarographic Determination of Trace Antimony in Standard Biological Samples after Preconcentration Using 2-Nitroso-1-naphthol-4-sulfonic Acid

A highly selective, sensitive, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of antimony in various standard alloys and biological samples after adsorption of its 2-nitroso-1-naphthol-4-sulfonic acid - tetradecyldimethylbenzylammonium chloride on microcrystalline naphthalene in the pH range of 7.5-11.0. After filtratio...

متن کامل

DIFFERENTIAL PULSE POLAROGRAPHIC DETERMINATION OF OSMIUM BY CATALYSIS OF PYROGALLOL-RED BROMATE REACTION

A highly sensitive differential pulse polarographic (DPP) method has been developed for the determination of trace amounts of osmium, based on the catalytic effect of osmium (VIII) on the oxidation of pyrogallol red (PGR) by sodium bromate at pH 7.00 and 25.0 0.1 ? C. The reaction rate was monitored by measuring the differential pulse cathodic current of the oxidation product of PGR and broma...

متن کامل

Simultaneous Determination of Traces of Lead and Cadmium in Various Samples by Differential Pulse Polarography after Adsorbing Their 1-(2-Pyridyazol)-2-Naphthol onto Microcrystalline Naphthalene

A highly selective, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of cadmium and lead present together in various standard alloys and biological samples after adsorption of their 1-(2-pyridylazo)-2-naphthol complexes on microcrystalline naphthalene. Cadmium and lead complexes are equantitatively adsorbed on microcrysta...

متن کامل

Nitrite Determination by the Differential Pulse Polarographic Method

In this work; the optimum conditions of the differential pulse polarographic method conditions of the polarographic reduction of diphenylnitrosoamine which was occured by nitrite ion and diphenylamine in perchloric acidic medium and thiocyanate ion as catalyst, were determined. At these polarogram conditions, nitrite ion gave a maximum diffusion current at -0.56 V. The differential pulse polaro...

متن کامل

Polarographic Behaviour and Analysis of Permethrin

The electrochemical reduction behaviour of Permethrin has been carried out, by employing d.c. polarography, cyclic voltammetry (CV) and differential pulse polarography (DPP) in the supporting electrolytes of the pH ranging from 2.0 to 12.0. The nature of electrode process was studied, the number of electrons was evaluated and the reduction mechanism was proposed. Kinetic parameters such as tran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Talanta

دوره 29 11 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1982