Studies on neutral, cationic and biotinylated cationic microbubbles in enhancing ultrasound-mediated gene delivery in vitro and in vivo.
نویسندگان
چکیده
Ultrasound-mediated gene transfer is emerging as a practical means of facilitating targeted gene expression and is significantly enhanced in the presence of exogenously added microbubbles. This study explores the influence of microbubble surface modifications on their interaction with plasmid DNA and target cells, and the functional consequences of those interactions in terms of ultrasound-mediated gene transfer. Polyethylene glycol-stabilized, lipid-shelled microbubbles with neutral (SDM201), cationic (SDM202) and biotinylated cationic (SDM302) surfaces were compared in terms of their abilities to interact with a luciferase-encoding reporter plasmid DNA and with target cells in vitro. The results demonstrate that the biotinylated cationic microbubble>cationic microbubble>neutral microbubble, in terms of their abilities to interact with target cells and to enhance ultrasound-mediated gene transfer, particularly at low microbubble concentration. The presence of a net positive charge on both cationic microbubbles promoted the formation of microbubble-nucleic acid complexes, although preformation of the complexes prior to addition to target cells inhibited the interaction between the microbubbles and target cells in vitro. The impact of these findings on potential in vitro or ex vivo therapeutic applications of microbubble-enhanced ultrasound-mediated gene transfer is discussed. All three microbubble preparations could be used to facilitate gene transfer in vivo and the potential advantages associated with the use of the cationic microbubbles for targeted gene delivery are discussed.
منابع مشابه
Cationic versus neutral microbubbles for ultrasound-mediated gene delivery in cancer.
PURPOSE To test whether plasmid-binding cationic microbubbles (MBs) enhance ultrasound-mediated gene delivery efficiency relative to control neutral MBs in cell culture and in vivo tumors in mice. MATERIALS AND METHODS Animal studies were approved by the institutional animal care committee. Cationic and neutral MBs were characterized in terms of size, charge, circulation time, and DNA binding...
متن کاملUltrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency
OBJECTIVE To assess the effect of varying microbubble (MB) and DNA doses on the overall and comparative efficiencies of ultrasound (US)-mediated gene delivery (UMGD) to murine hindlimb skeletal muscle using cationic versus neutral MBs. MATERIALS AND METHODS Cationic and control neutral MBs were characterized for size, charge, plasmid DNA binding, and ability to protect DNA against endonucleas...
متن کاملCationic gas-filled microbubbles for ultrasound-based nucleic acids delivery
The use of ultrasound has gained great interest for nucleic acids delivery. Ultrasound can reach deep tissues in non-invasive manner. The process of sonoporation is based on the use of low-frequency ultrasound combined with gas-filled microbubbles (MBs) allowing an improved delivery of molecules including nucleic acids in the insonified tissue. For in vivo gene transfer, the engineering of cati...
متن کاملExperimental endostatin-GFP gene transfection into human retinal vascular endothelial cells using ultrasound-targeted cationic microbubble destruction
PURPOSE The purpose of this study was to investigate whether ultrasound-targeted cationic microbubble destruction could effectively deliver endostatin-green fluorescent protein (ES-GFP) plasmids to human retinal vascular endothelial cells (HRECs). METHODS Cationic microbubbles (CMBs) were prepared and then compared with neutral microbubbles (NMBs) and liposomes. First, the two types of microb...
متن کاملTargeted Antiangiogenesis Gene Therapy Using Targeted Cationic Microbubbles Conjugated with CD105 Antibody Compared with Untargeted Cationic and Neutral Microbubbles
OBJECTIVE This study aimed to develop targeted cationic microbubbles conjugated with a CD105 antibody (CMB105) for use in targeted vascular endothelial cell gene therapy and ultrasound imaging. We compared the results with untargeted cationic microbubbles (CMB) and neutral microbubbles (NMB). METHODS CMB105 were prepared and compared with untargeted CMB and NMB. First, the microbubbles were c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta biomaterialia
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2012