Lower limits of fluorescein and indocyanine green dye for digital cSLO fluorescence angiography.
نویسندگان
چکیده
BACKGROUND With the advent of digital confocal scanning laser ophthalmoscopy it is possible to detect low levels of fluorescence. Here we used a novel confocal scanning laser ophthalmoscope (cSLO) to determine lower limits of dye required for fluorescein (FL) and indocyanine green (ICG) angiography. METHODS A cSLO (Heidelberg retina angiograph 2, Heidelberg Engineering, Dossenheim, Germany) with an optically pumped solid state laser (488 nm) for FL and a diode laser (790 nm) for ICG angiography (FL/ICG-A) was used. 62 FL-As were performed in 53 patients and 45 ICG-As were performed in 39 patients with neovascular age related macular degeneration. The volume and overall dye content of bolus injections was gradually tapered (FL: 500 mg, 250 mg, 200 mg, 166 mg, 100 mg; ICG: 25 mg, 20 mg, 15 mg, 10 mg, 5 mg, 2.5 mg), while dye concentrations were kept constant at 100 mg/ml for FL and at 5 mg/ml for ICG. Images were obtained 1, 5, 15, and 30 minutes after dye injection. Image quality was evaluated by two independent readers using standardised criteria. RESULTS For amounts down to 166 mg for FL and to 5 mg for ICG, sufficient image quality was achieved during all phases following injection. Only late phase images showed less contrast compared to typically used dye amounts, which was irrelevant for interpretation and clinical management. CONCLUSIONS With the increased sensitivity of this novel cSLO system, amounts of injected dye during FL-A can be reduced to one third for FL and to one fifth for ICG without relevant loss of image quality or information compared to conventionally used dye levels. These amounts can be used for routine angiography and allow relevant savings for units performing FL-A.
منابع مشابه
EXTENDED REPORT Lower limits of fluorescein and indocyanine green dye for digital cSLO fluorescence angiography
Background: With the advent of digital confocal scanning laser ophthalmoscopy it is possible to detect low levels of fluorescence. Here we used a novel confocal scanning laser ophthalmoscope (cSLO) to determine lower limits of dye required for fluorescein (FL) and indocyanine green (ICG) angiography. Methods: A cSLO (Heidelberg retina angiograph 2, Heidelberg Engineering, Dossenheim, Germany) w...
متن کاملInjection technique for indocyanine green and sodium fluorescein dye angiography of the eye.
This study was done in an effort to improve the intravenous dye injection technique used in fluorescent indocyanine green and sodium fluorescein dye angiography of the eye. The concentrations of these two dyes in blood at which maximum fluorescence occurs were determined, and methods of achieving these concentrations in the ocular vasculatures via cubital vein injection were investigated. The e...
متن کاملIntraoperative Near - infrared Indocyanine Green Videoangiography
Fluorescence angiography was first used by ophthalmologists to measure retinal blood flow by using the fluorescent dye fluorescein. Feindel et al.1,2 were the first to apply the concept of fluorescence angiography to the intraoperative visualisation of cerebral vertebral arteries and cerebral microcirculation in patients undergoing neurosurgical procedures.3,4 With the use of indocyanine green ...
متن کاملIndocyanine green fluorescence angiography of the choroid.
Indocyanine green fluorescence (ICG) angiography of the choroid gives better visualization of the choroidal vessels than does fluorescein angiography. We found that the detachment of the pigment epithelium seems bigger on ICG than on fluorescein angiograms, and pigmented lesions are more clearly delineated.
متن کاملIn-House Handmade Camera for Indocyanine Green Video Angiography
Background and Aim: Vascular imaging during surgical procedures is very important and has many applications. There are several methods for intraoperative vascular assessment such as intraoperative angiography, Doppler, and fluorescence-based techniques. The latter group and specially the Indocyanine Green (ICG) Video Angiography (VA) is commonly used for vascular surgery and sentinel node...
متن کاملذخیره در منابع من