Bacteria in a water-damaged building: associations of actinomycetes and non-tuberculous mycobacteria with respiratory health in occupants.
نویسندگان
چکیده
We examined microbial correlates of health outcomes in building occupants with a sarcoidosis cluster and excess asthma. We offered employees a questionnaire and pulmonary function testing and collected floor dust and liquid/sludge from drain tubing traps of heat pumps that were analyzed for various microbial agents. Forty-nine percent of participants reported any symptom reflecting possible granulomatous disease (shortness of breath on exertion, flu-like achiness, or fever and chills) weekly in the last 4 weeks. In multivariate regressions, thermophilic actinomycetes (median = 529 CFU/m2 ) in dust were associated with FEV1 /FVC [coefficient = -2.8 per interquartile range change, P = 0.02], percent predicted FEF25-75% (coefficient = -12.9, P = 0.01), and any granulomatous disease-like symptom [odds ratio (OR) = 3.1, 95% confidence interval (CI) = 1.45-6.73]. Mycobacteria (median = 658 CFU/m2 ) were positively associated with asthma symptoms (OR = 1.5, 95% CI = 0.97-2.43). Composite score (median = 11.5) of total bacteria from heat pumps was negatively associated with asthma (0.8, 0.71-1.00) and positively associated with FEV1 /FVC (coefficient = 0.44, P = 0.095). Endotoxin (median score = 12.0) was negatively associated with two or more granulomatous disease-like symptoms (OR = 0.8, 95% CI = 0.67-0.98) and asthma (0.8, 0.67-0.96). Fungi or (1→3)-β-D-glucan in dust or heat pump traps was not associated with any health outcomes. Thermophilic actinomycetes and non-tuberculous mycobacteria may have played a role in the occupants' respiratory outcomes in this water-damaged building.
منابع مشابه
A Review on Environmental Mycobacteria in Iran
Abstract Mycobacterium genus, including pathogenic and environmental species, is called non-tuberculosis mycobacteria. In this review, we assessed the research about the frequency of non-tuberculosis mycobacteria in Iran. The analyses showed that there are 16 and 28 mycobacterial species isolated in water and soil samples, respectively. The most frequent mycobacterial species in water were M. f...
متن کاملEvaluation Drug Susceptibility of Clinical Isolates of Mycobacterium Simiea Using REMA Plate Method in Mashhad
Introduction: Non-tuberculous species of Mycobacterium are a large group of Mycobacterium and are widely distributed throughout the world. Increased isolation of non-tuberculous mycobacteria from patients with mycobacteria infections in Iranian laboratories was associated with erroneous and unnecessary drug treatment, so that in some cases isolated strains considered as drug resistant strains. ...
متن کاملSarcoidosis, asthma, and asthma-like symptoms among occupants of a historically water-damaged office building.
UNLABELLED Sarcoidosis is a granulomatous disease of unknown etiology with evidence of association with exposure to microbial agents. In June 2006, we investigated a sarcoidosis cluster among office workers in a water-damaged building. In the course of the investigation, we became aware of a high rate of respiratory complaints including asthma and asthma-like symptoms. We conducted case finding...
متن کاملNon-tuberculous mycobacteria in cystic fibrosis.
BACKGROUND The clinical significance of the presence of non-tuberculous mycobacteria in the sputum of patients with cystic fibrosis is unclear. A retrospective case-control study was performed to assess possible risk factors for non-tuberculous mycobacteria and its impact on clinical status in patients with cystic fibrosis. METHODS The records of all patients attending the Leeds cystic fibros...
متن کاملEffectiveness of Energy Retrofit on Energy Consumption and Occupants' Comfort: Case of Shahid Beheshti University Dorimitories
In addition to the building properties effect on energy consumption, it is important to consider occupant’s energy behavior and their interaction with building systems in energy calculations. According to studies, energy retrofit regardless of considering this factor, has a lower effect on reducing the energy consumption. This study investigates the impact of energy retrofit in two (retrofitted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indoor air
دوره 27 1 شماره
صفحات -