Rapid assessment of perfusion-diffusion mismatch.

نویسندگان

  • Ken Butcher
  • Mark Parsons
  • Louise Allport
  • Sang Bong Lee
  • P Alan Barber
  • Brian Tress
  • Geoffrey A Donnan
  • Stephen M Davis
چکیده

BACKGROUND AND PURPOSE For MR perfusion-diffusion (PWI-DWI) mismatch to become routine in thrombolysis patient selection, rapid and reliable assessment tools are required. We examined interrater variability in PWI/DWI volume measurements and developed a rapid assessment tool based on the Alberta Stroke Program Early CT Scores (ASPECTS) system. METHODS DWI and PWI were performed in 35 patients with stroke <6 hours after symptom onset. DWI lesion and PWI (time to peak) volumes were measured with planimetric techniques by 4 raters and the 95% limits of agreement calculated. ASPECT scores were assessed separately by 4 investigators (2 experienced and 2 inexperienced) for DWI (MR DWI scores) and PWI (MR time to peak scores). MR mismatch scores were calculated as MR DWI-MR time to peak scores. RESULTS Interobserver variability was much greater for PWI (95% limit of agreement=+/-72.3 mL) than for DWI (95% limit of agreement=+/-12.6 mL). A semiautomated PWI volume (time to peak+2 s) was therefore used to calculate mismatch volume. MR mismatch scores >or=2 predicted 20% PWI-DWI mismatch by volume with mean 78% sensitivity (range, 72% to 84%) and 88% specificity (range, 83% to 90%). There was excellent agreement on mismatch classification using MR mismatch scores between experienced raters (weighted kappa scores of 0.94) with agreement in 34 of 35 cases. Agreement was less consistent between inexperienced raters (weighted kappa=0.49, 28 of 35 cases). CONCLUSIONS Variability in planimetric mismatch measurements arises primarily from differences in PWI volume assessment. High specificity and interrater reliability may make MR mismatch scores an ideal rapid screening tool for potential thrombolysis patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ASPECTS (Alberta Stroke Program Early CT Score) Assessment of the Perfusion-Diffusion Mismatch.

BACKGROUND AND PURPOSE Rapid and reliable assessment of the perfusion-weighted imaging (PWI)/diffusion-weighted imaging (DWI) mismatch is required to promote its wider application in both acute stroke clinical routine and trials. We tested whether an evaluation based on the Alberta Stroke Program Early CT Score (ASPECTS) reliably identifies the PWI/DWI mismatch. METHODS A total of 232 consecu...

متن کامل

Reliability of assessing percentage of diffusion-perfusion mismatch.

BACKGROUND AND PURPOSE Emergent neurovascular imaging holds promise in identifying new and optimum target populations for thrombolysis in stroke. Recent research has focused on patients with diffusion-weighted MRI (DWI)-perfusion-weighted MRI (PWI) mismatch as a marker of tissue at risk of infarction and a means to select the most suitable candidates for thrombolysis. The present study sought t...

متن کامل

RAPID automated patient selection for reperfusion therapy: a pooled analysis of the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET) and the Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution (DEFUSE) Study.

BACKGROUND AND PURPOSE The aim of this study was to determine if automated MRI analysis software (RAPID) can be used to identify patients with stroke in whom reperfusion is associated with an increased chance of good outcome. METHODS Baseline diffusion- and perfusion-weighted MRI scans from the Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution study (DEFUSE; n=74) ...

متن کامل

Rapid identification of a major diffusion/perfusion mismatch in distal internal carotid artery or middle cerebral artery ischemic stroke

BACKGROUND We tested the hypothesis that in patients with occlusion of the terminal internal carotid artery and/or the proximal middle cerebral artery, a diffusion abnormality of 70 ml or less is accompanied by a diffusion/perfusion mismatch of at least 100%. METHODS Sixty-eight consecutive patients with terminal ICA and/or proximal MCA occlusions and who underwent diffusion/perfusion MRI wit...

متن کامل

Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.

BACKGROUND AND PURPOSE Perfusion imaging has the potential to select patients most likely to respond to thrombolysis. We tested the correspondence of computed tomography perfusion (CTP)-derived mismatch with contemporaneous perfusion-diffusion magnetic resonance imaging (MRI). METHODS Acute ischemic stroke patients 3 to 6 hours after onset had CTP and perfusion-diffusion MRI within 1 hour, be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 2008