Improved accuracy and precision of thermodilution cardiac output measurement using a dual thermistor catheter system.
نویسندگان
چکیده
OBJECTIVES To assess whether thermodilution cardiac output determination based on measurement of injectate temperature in vivo leads to more accurate and precise estimates and to study the influence of chilled injectate on test performance. BACKGROUND Cardiac output measurement via right heart catheterization is used extensively for hemodynamic evaluation in a variety of diagnostic, perioperative and critical care settings. Maximizing accuracy is essential for optimal patient care. METHODS This prospective study of 960 thermodilution cardiac output measurements was conducted using conventional and dual thermistor techniques. Specialized dual thermistor right heart catheters were constructed using a second thermistor positioned to measure injectate temperature in vivo just prior to entry into the right atrium. To eliminate interinjection variability, a custom set-up was developed that permitted output measurement using both techniques simultaneously. Both ambient temperature injections and cooled injections were investigated. RESULTS The dual thermistor technique demonstrated significantly less measurement variability than the conventional technique for both ambient temperature (precision = 0.41 vs. 0.55 L/min, p < 0.001) and cooled (precision = 0.35 vs. 0.43 L/min, p = 0.01) injections. Similarly, the average range of cardiac output values obtained during five sequential injections in each patient was less using the dual thermistor approach (1.05 vs. 1.55 L/min, p < 0.001). The use of cooled injectate reduced the mean error of the dual thermistor technique but actually increased the mean error of the conventional technique. Even with ambient temperature injections, injectate warming during catheter transit varied considerably and unpredictably from injection to injection (2 SD range = -0.22 to 5.74 degrees C). Conventional ambient temperature and cooled measurements significantly overestimated Fick cardiac output measurements by 0.32 and 0.50 L/min, respectively (p < 0.001). In contrast, dual thermistor measurements were statistically similar (-0.08 and -0.08 L/min, p = 0.34) to Fick measurements. CONCLUSIONS This new dual thermistor approach results in a significant improvement in both precision and accuracy of thermodilution cardiac output measurement.
منابع مشابه
An In Vitro Calibration of the Thermodilution Method of Cardiac Output Determination
____________ _ (/. Extra-Corpor. Techno/. 19[2) p. 221-227 Summer 1987, 13 refs.) The accuracy of cardiac output (Q) determinations by the indicator dilution method will depend, amongst other things, upon the precision of the instruments used to make the measurements. Using an in vitro calibration we determined the accuracy and reproducibility of the measured flow from three different thermodil...
متن کاملComparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output.
A new indicator dilution technique for measurement of cardiac output is described. Lithium chloride is injected via a central venous catheter and its dilution curve measured in arterial blood using a lithium-selective electrode. We assessed the lithium dilution cardiac output measurement (LiDCO) and a conventional thermodilution cardiac output measurement (ThDCO) by comparing the results of bot...
متن کاملRadial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery.
OBJECTIVES Radial artery applanation tonometry allows completely noninvasive continuous cardiac output estimation. The aim of the present study was to compare cardiac output measurements obtained with applanation tonometry (AT-CO) using the T-Line system (Tensys Medical, San Diego, CA) with cardiac output measured by intermittent pulmonary artery thermodilution using a pulmonary artery catheter...
متن کامل[Comparison of cardiac output measurement in critical patients using transesophageal Doppler or thermodilution: a preliminary report].
BACKGROUND Cardiac output can be measured non invasively by transesophageal Doppler. This is an alternative to measure it by thermodilution with a catheter in the pulmonary artery. AIM To compare both methods of cardiac output measurement. MATERIAL AND METHODS Simultaneous measurement of cardiac output by transesophageal Doppler and thermodilution with a catheter in the pulmonary artery in ...
متن کاملLack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients
BACKGROUND: Bolus thermodilution is the standard bedside method of cardiac output measurement in the intensive care unit (ICU). The Baxter Vigilance monitor uses a modified thermodilution pulmonary artery catheter with a thermal filament to give a continuous read-out of cardiac output. This has been shown to correlate very well with both the 'gold standard' dye dilution method and the bolus the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 33 3 شماره
صفحات -
تاریخ انتشار 1999