PA.NET International Quality Certification Protocol for blood pressure monitors.
نویسندگان
چکیده
Although standard validation protocols provide assurance of the accuracy of blood pressure monitors (BPMs), there is no guidance for the consumer as to the overall quality of a device. The PA.NET International Quality Certification Protocol, developed by the Association for Research and Development of Biomedical Technologies and for Continuing Medical Education (ARSMED), a nonprofit organization, with the support of the Italian Society of Hypertension-Italian Hypertension League, and the dabl Educational Trust denotes additional criteria of quality for BPMs that fulfilled basic validation criteria, published in full in peer-reviewed medical journals. The certification is characterized by three phases: (i) to determine that the device fulfilled standard validation criteria; (ii) to determine the technical and functional characteristics of the device (e.g. operativity, display dimension, accessory functions, memory availability, etc.) and (iii) to determine the commercial characteristics (e.g. price-quality ratio, after-sale service, guarantee, etc.). At the end of the certification process, ARSMED attributes a quality index to the device, based on a scale ranging from 1 to 100, and a quality seal with four different grades (bronze, silver, gold and diamond) according to the achieved score. The seal is identified by a unique alphanumeric code. The quality seal may be used on the packaging of the appliance or in advertising. A quality certification is released to the manufacturer and published on www.pressionearteriosa.net and www.dableducational.org. The PA.NET International Quality Certification Protocol represents the first attempt to provide health care personnel and consumers with an independent and objective assessment of BPMs based on their quality.
منابع مشابه
Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010
BACKGROUND Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. T...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملResponse to--Blood Pressure Monitoring 2011; 16: 67-73.
The authors would like to comment on the manuscript by Stergiou et al. [1]. The authors make incorrect assumptions in both the introduction and conclusion of the article related to the significance of the European Society of Hypertension International Protocol (ESH-IP). In the article’s introduction, the authors state that the ESH-IP 2002 is the most widely used protocol for noninvasive blood p...
متن کاملElectromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors
Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...
متن کاملEuropean Society of Hypertension International Protocol for the validation of blood pressure monitors: a critical review of its application and rationale for revision.
OBJECTIVE To perform a systematic review of validation studies of blood pressure measuring devices done using the European Society of Hypertension International Protocol (ESH-IP) since its publication in 2002. METHODS Major aspects of ESH-IP studies are described. A review of the ESH-IP performance, problems and violations in its application, and the effect of applying several more stringent ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Blood pressure monitoring
دوره 13 5 شماره
صفحات -
تاریخ انتشار 2008