Analytical variance and definition of a reference change as a function of calcium concentration.
نویسندگان
چکیده
Using data from the Centers for Disease Control (CDC) Proficiency Testing (PT) Surveys, we obtained estimates of repeatability (intralaboratory variability between results on the same material) and reproducibility (interlaboratory variability between results on the same material) for the Technicon SMA 6 (or 12/60) and SMAC 1 (or II) systems used with cresolphthalein complexone methodology to measure serum calcium. The two systems were comparable in terms of short-term (within-day) repeatability, long-term (three to six months) repeatability, short-term (one to two weeks) reproducibility, and long-term (three to six months) reproducibility. The long-term repeatability was essentially the same as the long-term reproducibility. Short-term repeatability, long-term repeatability, and long-term reproducibility increased linearly with increased calcium concentration over the range 1.75 to 2.95 mmol/L; short-term reproducibility showed no significant change over this range. The effect of analytical variance on the definition of a reference change in semiannual calcium measurements was demonstrated.
منابع مشابه
پیشگویی کننده های انجام رفتارهای پیشگیری کننده از پوکی استخوان در بین زنان: کاربرد الگوی فرانظری
Background and Objectives: Behavioral change is one of the most powerful strategies for preventing osteoporosis. The aim of this study was to investigate the osteoporosis preventive behaviors in women based on the transtheoretical model. Materials and Methods: This cross sectional descriptive-analytical study was performed on 400 women over 30 years covered by Fasa health care cent...
متن کاملProjects performance evaluation model based on Choquet Integral
In most of the multi–criteria decision–analysis (MCDA) problems in which the Choquet integral is used as aggregation function, the coefficients of Choquet integral (capacity) are not known in advance. Actually, they could be calculated by capacity definition methods. In these methods, the preference information of decision maker (DM) is used to constitute a possible solution space. ...
متن کاملWeber's law orthogonal to the psychometric function
Psychometric function plots the percentage of the correct responses among an entire pool of responses (cumulative probability) in a psychophysical task versus the amount of change in an independent variable. These changes in the independent variable are made with reference to a constant initial value. If this initial value is altered, the psychometric function will change according to Weber’s l...
متن کاملWeber's law orthogonal to the psychometric function
Psychometric function plots the percentage of the correct responses among an entire pool of responses (cumulative probability) in a psychophysical task versus the amount of change in an independent variable. These changes in the independent variable are made with reference to a constant initial value. If this initial value is altered, the psychometric function will change according to Weber’s l...
متن کاملRole of Calcium Content in Dissolution Kinetics of Iranian Borate Minerals in Sulfuric Acid
The dissolution kinetics of pandermite and hydroboracite, present in an Iranian borate ore, in sulfuric acid has been comparatively studied. The effect of particle size, temperature, and acid concentration on their dissolution rate was investigated. Dissolution rates of both minerals increased by reducing the particle size and by raising the temperature. Although, an increase in the acid concen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1986