An Impact of the Efficient Functioning of the Ventilation and Air-conditioning System on Thermal Comfort of the Medical Staff in the Operating Room
نویسندگان
چکیده
Ventilation and air conditioning systems are necessary for developing proper parameters of indoor environment in operating rooms. The main task of ventilation and air conditioning in those specific areas consists in creating desirable temperature, reducing the number of microorganisms and the concentrations of hazardous gases and substances in the air, as well as ensuring the proper direction of airflow. In Poland, indoor environment in operating rooms has to comply with the requirements set out in three regulations (Journal of Laws of 2002 No. 75, item 690, as amended, Journal of Laws of 2002 No. 217, item 1833, Journal of Laws of 2011 No. 31, item 158, as amended) and the document entitled “Guidelines for the design of general hospitals”. Given insufficient accuracy of the abovementioned national documents, it is a common practice to use foreign standards, i.e. ASHRAE Standard 170–2013, DIN 1946-4: 2008 and FprCEN TR 16244: 2011. When considering the conditions for thermal comfort, it is important to bear in mind a close link between air flow velocity and air temperature. Air in the zone occupied by patients and medical staff must not cause the sensation of draft. Furthermore, air velocity should be sufficient to eliminate interference caused by the presence of people and other sources of heat. It should also reduce the turbulence level in the air in the operating room. Efficient functioning of ventilation and air conditioning was tested during treatments and operations carried out on three wards of a Warsaw hospital. Tests were performed with the participation of medical staff from various surgical units. They were asked to perform minor manual tasks to simulate work on the operating table, and to complete a questionnaire on subjective thermal sensation. The applied methodology is widely used during testing of general and local ventilation in public buildings. Air temperature, relative humidity, air flow supply and exhaust air from the operating room were determined on the basis of VelociCalc 8360 and Testo 435 anemometers with a 3-function probe and 3 vane probes with the diameter of 16 mm, 60 mm and 100 mm. Throughout the study, microclimate conditions in the operating rooms were controlled by the EHA MM101 microclimate meter. Test results showed that the microclimate parameters met the requirements of the aforementioned documents. However, individual thermal sensations reported by the medical staff pointed to the lack of thermal comfort and, in extreme cases, e.g. when using lead aprons during operations, perception of the thermal environment as ‘very hot’. The efficiency and type of air distribution in operating rooms has a decisive effect on the results.
منابع مشابه
Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملEffect of Velocity and Direction of Airflow on Thermal Comfort and Energy Consumption: Case of New Exclusive Cooling Systems
The application of personalized ventilation systems, particularly in the buildings, is one of the new topics that today presented to it, because of their proper performance in reducing energy consumption and creating better thermal comfort conditions. In the current study, the energy consumption of a personalized cooling system installed in a room, considering the constraint of thermal comfort,...
متن کاملThermal comfort of the surgical staff in an operating theatre: a numerical study on laminar and mixing ventilation systems
The indoor air quality in an operating theatre affects both patient health and the well-being of the surgical team members. Health care facilities, and operating theatres in particular, require ventilation and air conditioning for thermal comfort and removal of contaminants. Although the patient undergoing surgery is given the highest priority, it is important to consider the comfort of surgica...
متن کاملEffect of opening diffuser and return vent location on air quality, thermal comfort and energy saving in desk displacement ventilation (DDV) system
Many investigations have recently been performed on return vent height and indicate that having 1.3 m distance from the floor is the optimized height for it. In this article, the effect of distance between opening diffuser and return vent on air quality, thermal comfort and energy saving was investigated. According to the results, by increasing the distance between opening and return vent up to...
متن کاملLocal ventilation system designed to respirable particles reduce in Abrasive vitrified unit
Background: the importance of clean air is well known in industrial environments. Industries used in numerous Chemicals that many of them are toxic. Proper industrial ventilation can create a sense of calm and comfort for the staff, as a result of which the staff performs well and will have a positive impact on their performance. This study was aimed to determine the concentration of air pollut...
متن کامل