Analysis of passive calorimetric probe measurements at high energy influxes
نویسندگان
چکیده
High energy influxes increase the complexity of passive calorimetric probe measurements because of an increasing temperature of the surrounding materials like the probe holder. This leads to a distinctively different evolution of the probe temperature compared to low energy influxes. Different established methods for the analysis of passive calorimetric probe data are presented and it is shown that they are not applicable for high energy influx measurements resulting in the requirement of a novel analysis approach. Such an approach is given in this paper by the combination of the exponential and the linear method. The high energy influx measurements are studied for a commercial atmospheric pressure plasma jet, in order to illustrate our suggested modified approach.
منابع مشابه
Evaluation and Characterization of Free and Immobilized Acethylcholinesterase with Fluorescent Probe, Differential Scanning Calorimetry and Docking
Acetylcholinesterase (AChE) enzyme which catalyses the hydrolysis of choline esters, such as acetylcholine, is very important in nerve function. Previous structural studies showed the possible amyloid fibril formation on the AChE. Therefore it is important to understand interaction of ligands to prevent the formation of amyloid fibrils. The purpose of the present study was to char...
متن کاملCalorimetric transverse energy-energy correlations as a probe of jet quenching
The sensitivity of calorimetric energy-energy correlation function to the mediuminduced energy loss of fast partons in high multiplicity heavy ion interactions is demonstrated at the appropriate selection of events for the analysis, namely, the availability of one high-pT jet in an event at least and using the procedure of “thermal” background subtraction. Without jet trigger this correlation f...
متن کاملComparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar
Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of rado...
متن کاملPassive and active microrheology of hard-sphere colloids.
We performed passive and active microrheology using probe particles in a bath of well-characterized, model hard-sphere colloids in the fluid state over the whole range of volume fractions below the glass transition. The probe and bath particles have nearly the same size. Passive tracking of probe particles yields short-time self-diffusion coefficients. Comparison with literature data demonstrat...
متن کاملSystematic errors in ground heat flux estimation and their correction
[1] Incoming radiation forcing at the land surface is partitioned among the components of the surface energy balance in varying proportions depending on the time scale of the forcing. Based on a land-atmosphere analytic continuum model, a numerical land surface model, and field observations we show that high-frequency fluctuations in incoming radiation (with period less than 6 h, for example, d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017