Removal of Baseline Fluctuation from Emg Recordings

نویسندگان

  • Sadhana Pal
  • Gyan Prakash
  • Prakash Pal
چکیده

1. Abstract: Appropriate cancellation of the baseline fluctuation (BLF) is an important issue when recording EMG signals as it may degrade signal quality and distort qualitative and quantitative analysis. We present statistical and filter-design approach for cancellation of the BLF based on several signal processing techniques used sequentially. The methodology is to estimate the spectral contents of the BLF, and then to use this estimation to design a high pass Butterworth filter by using Bilinear Transformation that cancel the BLF present in the signal. Two merit figures are devised for measuring the degree of BLF present in an EMG record. These figures are used to compare both methods which naively consider the baseline without any fluctuation i.e. constant potential shift. Applications of the techniques on real and simulated EMG signals show the superior performance of our approach in terms of both visual inspection and the merit figures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of Baseline Fluctuation in EMG Signal Using Digital Filter

Electromyography (EMG) is the study of the skeletal muscle function and the contraction of the skeletal muscle result in the generation of action potential in the individual muscle fibers, it from get information in the diagnosis of neuromuscular disorders. Suitable removal of baseline fluctuation of EMG signals is very important issue when recoding EMG signals as it may be degrade quality and ...

متن کامل

Techniques of Removal of Baseline Fluctuation from EMG Signal Recordings

Appropriate cancellation of the baseline fluctuation (BLF) is an important issue when recording EMG signals as it may degrade signal quality and distort qualitative and quantitative analysis. We present two techniques, statistical and filter-design approach for cancellation of the BLF based on several signal processing techniques used sequentially. The methodology is to estimate the spectral co...

متن کامل

Comparative Study of Various Techniques for Elimination of Noise in Emg Signal

Electromyography (EMG) is the study of electrical activity of muscle and it form valuable information in the diagnosis of neuromuscular disorders. EMG signal may be degraded by a noise; it is in the baseline of EMG signal. It is called baseline fluctuation of EMG signal. Baseline fluctuation distorts qualitative and quantitative analysis. The present work focus on various techniques and their c...

متن کامل

Comparative Analysis for Cancellation of Baseline- Fluctuation in Emg Signal

---------------------------------------------------------------------***--------------------------------------------------------------------Abstract Electromyography (EMG) is an electrodiagnostic technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG is performed using an instrument called an Electromyograph, to produce a record called an Electromyogram...

متن کامل

High-pass filtering to remove electrocardiographic interference from torso EMG recordings.

UNLABELLED Removal of electrocardiographic (ECG) contamination of electromyographic (EMG) signals from torso muscles is often attempted by high-pass filtering. This study investigated the effects of the cut-off frequency used in this high-pass filtering technique on the resulting EMG signal. Surface EMGs were recorded on five subjects from the rectus abdominis, external oblique, and erector spi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011