Using FLIM-FRET to Measure Conformational Changes of Transglutaminase Type 2 in Live Cells

نویسندگان

  • Nicholas S. Caron
  • Lise N. Munsie
  • Jeffrey W. Keillor
  • Ray Truant
چکیده

Transglutaminase type 2 (TG2) is a ubiquitously expressed member of the transglutaminase family, capable of mediating a transamidation reaction between a variety of protein substrates. TG2 also has a unique role as a G-protein with GTPase activity. In response to GDP/GTP binding and increases in intracellular calcium levels, TG2 can undergo a large conformational change that reciprocally modulates the enzymatic activities of TG2. We have generated a TG2 biosensor that allows for quantitative assessment of TG2 conformational changes in live cells using Förster resonance energy transfer (FRET), as measured by fluorescence lifetime imaging microscopy (FLIM). Quantifying FRET efficiency with this biosensor provides a robust assay to quickly measure the effects of cell stress, changes in calcium levels, point mutations and chemical inhibitors on the conformation and localization of TG2 in living cells. The TG2 FRET biosensor was validated using established TG2 conformational point mutants, as well as cell stress events known to elevate intracellular calcium levels. We demonstrate in live cells that inhibitors of TG2 transamidation activity can differentially influence the conformation of the enzyme. The irreversible inhibitor of TG2, NC9, forces the enzyme into an open conformation, whereas the reversible inhibitor CP4d traps TG2 in the closed conformation. Thus, this biosensor provides new mechanistic insights into the action of two TG2 inhibitors and defines two new classes based on ability to alter TG2 conformation in addition to inhibiting transamidation activity. Future applications of this biosensor could be to discover small molecules that specifically alter TG2 conformation to affect GDP/GTP or calcium binding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring Biosensor Activity in Living Cells with Fluorescence Lifetime Imaging Microscopy

Live-cell microscopy is now routinely used to monitor the activities of the genetically encoded biosensor proteins that are designed to directly measure specific cell signaling events inside cells, tissues, or organisms. Most fluorescent biosensor proteins rely on Förster resonance energy transfer (FRET) to report conformational changes in the protein that occur in response to signaling events,...

متن کامل

A dark green fluorescent protein as an acceptor for measurement of Förster resonance energy transfer

Measurement of Förster resonance energy transfer by fluorescence lifetime imaging microscopy (FLIM-FRET) is a powerful method for visualization of intracellular signaling activities such as protein-protein interactions and conformational changes of proteins. Here, we developed a dark green fluorescent protein (ShadowG) that can serve as an acceptor for FLIM-FRET. ShadowG is spectrally similar t...

متن کامل

FLIM FRET Technology for Drug Discovery: Automated Multiwell-Plate High-Content Analysis, Multiplexed Readouts and Application in Situ**

A fluorescence lifetime imaging (FLIM) technology platform intended to read out changes in Förster resonance energy transfer (FRET) efficiency is presented for the study of protein interactions across the drug-discovery pipeline. FLIM provides a robust, inherently ratiometric imaging modality for drug discovery that could allow the same sensor constructs to be translated from automated cell-bas...

متن کامل

Time-domain fluorescence lifetime imaging microscopy: a quantitative method to follow transient protein-protein interactions in living cells.

Quantitative analysis in Förster resonance energy transfer (FRET) imaging studies of protein-protein interactions within live cells is still a challenging issue. Many cellular biology applications aim at the determination of the space and time variations of the relative amount of interacting fluorescently tagged proteins occurring in cells. This relevant quantitative parameter can be, at least ...

متن کامل

Quantitative analysis of chromatin compaction in living cells using FLIM–FRET

We present a quantitative Förster resonance energy transfer (FRET)-based assay using multiphoton fluorescence lifetime imaging microscopy (FLIM) to measure chromatin compaction at the scale of nucleosomal arrays in live cells. The assay uses a human cell line coexpressing histone H2B tagged to either enhanced green fluorescent protein (FP) or mCherry FPs (HeLa(H2B-2FP)). FRET occurs between FP-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012