Serial dilution with Takatsy loops resulted in exaggerated passive hemagglutination titers with most of the anti-bovine serum albumin sera tested. It appears that certain types of agglutinins adhere to the loop surface and are released only gradually. This adherence, or carry-over effect, was prevented by presoaking loops in gelatin or gelatin-rabbit serum-albumin solutions. Hemolysins did not adhere to loops. In general, hemagglutination reactions performed on plastic trays gave higher titers than those performed in glass test tubes. The quality of the hemagglutination pattern was dependent to a great extent on the type of plastic tray used. As much as a 100-fold difference in titers was obtained depending on the composition of the antiserum diluent. The increase in vibration, in terms of linear displacement (approximately twofold), resulted in an eightfold decrease in titers.
منابع مشابه
Detection of foot-and-mouth disease virus antibodies. II. Use of fractionated bovine antisera for improving the specificity of a "passive" hemagglutination test.
Because 7S immunoglobulin (Ig) G antibodies of low type specificity were present in mixtures with highly specific 19S IgM antibodies, many bovine antisera to foot-and-mouth disease virus (FMDV) type A(12), strain 119 cross-reacted with type O of FMDV and to some degree with type C in the passive hemagglutination (HA) test. After 19S IgM antibodies were separated by density gradient centrifugati...
متن کاملMicrotiter indirect hemagglutination procedure for identification of streptococcal M-protein antibodies.
A number of investigators have attempted to utilize the hemagglutination system for detection of streptococcal type-specific antibody in human sera. Cross-reactions have made the procedure unreliable without cumbersome and time-consuming manipulation of the test sera. A method is described in which a microtiter indirect hemagglutination technique, using sensitized sheep erythrocytes, is sensiti...
متن کاملSerological studies of types A, B, and E botulinal toxins by passive hemagglutination and bentonite flocculation.
Johnson, H. M. (Robert A. Taft Sanitary Engineering Center, Cincinnati, Ohio), K. Brenner, R. Angelotti, and H. E. Hall. Serological studies of types A, B, and E botulinal toxins by passive hemagglutination and bentonite flocculation. J. Bacteriol. 91:967-974. 1966.-Formalinized sheep red blood cells (SRBC), sensitized with types A, B, and E botulinal toxoids and toxins by bis-diazotized benzid...
متن کاملEffect of a modified kaolin treatment on serum immunoglobulins.
After kaolin treatment of fetal rabbit serum, 7S antibody titers were reduced more than 19S titers. This reduction was less when the kaolin treatment was performed at pH 9.0 than when it was performed at pH 7.3. A modification of the kaolin treatment of sera for use in the hemagglutination-inhibiting antibody titration, in which the hemagglutination reaction is performed at a neutral pH, is rec...
متن کاملDetection and titration of measles virus antibody by hemagglutination inhibition and by dot immunobinding.
Measles continues to be a major disease of both human and nonhuman primates. The dot immunobinding assay, a modified enzyme immunoassay, permits the detection of measles virus antibody in the nonlaboratory setting with either serum or whole blood collected on filter paper.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied microbiology
دوره 17 4 شماره
صفحات -
تاریخ انتشار 1969