Transvenous cardiac pacing. Experience of a percutaneous supraclavicular approach.

نویسندگان

  • M B Macaulay
  • J S Wright
چکیده

A detailed description is given of a technique for the introduction of cardiac pacing catheters using a percutaneous supraclavicular route through the subclavian vein. In 91 attempts there was only one failure and the frequency of complications was low. Surface landmarks for the procedure were easy to define precisely, and stable pacing could usually be established rapidly without distress to the patient or subsequent immobilization of any limb. It is suggested that operators with little experience of cardiac catheterization might find this approach valuable in the emergency pacing of acute heart block. Subclavian venepuncture does not appear to be as hazardous as has previously been suggested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Leadless cardiac pacing

Transvenous cardiac pacemakers definitely improve quality of life and reduce mortality in at-risk patients, but they are associated with several potential device-related complications. Approximately 10% of patients experience complications related to transvenous implantation of the pacemaker. These may be attributable to either the pulse generator (hematoma, skin breakdown, pocket infection) or...

متن کامل

Long term transvenous ventricular pacing in adults with congenital abnormalities of the heart and great arteries.

Improved techniques of transvenous pacing have made it possible to use this approach in various congenital cardiac abnormalities. Transvenous active fixation pacing leads were implanted in seven patients aged 15 to 81 years with abnormal venous, atrioventricular, or ventriculoarterial connections with successful ventricular pacing.

متن کامل

Recent Advances in Pacing and Defibrillation

Most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Vascular access may be difficult or limited in some patients, and intravascular leads can be associated with multiple complications such as infection, lead malfunction and vascular occlusion. Recent advances in pacing and ICDs include the development of subcutaneous ...

متن کامل

The Association between B-type Natriuretic Peptide Family and Successful Percutaneous Transvenous Mitral Commissurotomy: A Systematic Review

B-type natriuretic peptide (BNP) level is known to increase in patients with rheumatic mitral stenosis. In this systematic review, we aimed to discuss the possible association between plasma BNP level and the success rate of percutaneous transvenous mitral commissurotomy. PubMed and Scopus databases were searched systematically, using the following key terms: “B-type natriuretic peptide” OR “BN...

متن کامل

Current practice in transvenous lead extraction: a European Heart Rhythm Association EP Network Survey.

AIM Current practice with regard to transvenous lead extraction among European implanting centres was analysed by this survey. METHODS AND RESULTS Among all contacted centres, 164, from 30 countries, declared that they perform transvenous lead extraction and answered 58 questions with a compliance rate of 99.9%. Data from the survey show that there seems to be an overall increasing experience...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 4 5729  شماره 

صفحات  -

تاریخ انتشار 1970