Induced optical aberrations following formation of a laser in situ keratomileusis flap.

نویسندگان

  • Ioannis G Pallikaris
  • George D Kymionis
  • Sophia I Panagopoulou
  • Charalambos S Siganos
  • Michalis A Theodorakis
  • Aristofanis I Pallikaris
چکیده

PURPOSE To determine how refractive error, visual acuity, and high-order aberrations (3rd- and 4th-order) are affected by the formation of a lamellar corneal flap during laser in situ keratomileusis (LASIK). SETTING University refractive surgery center. METHODS The effect of lamellar corneal flap formation was analyzed in 15 myopic eyes (mean preoperative refraction -4.72 diopters [D] [range -1.25 to -7.25 D]). The flap was created using a 2-step procedure: (1). a nasally hinged lamellar corneal flap was created; (2). the flap was lifted and stromal ablation performed 2 months after the flap was made. A Hartmann-Shack aberrometer was used to measure the aberrations. RESULTS There was no significant change in the refractive error (spherical equivalent pre-flap -4.72 +/- 1.99 D and post-flap -4.62 +/- 1.99 D [P =.28]) or visual acuity (pre-flap uncorrected visual acuity [UCVA] 0.07 and best corrected visual acuity [BCVA] 0.96; post-flap UCVA 0.08 and BCVA 0.95 [P =.16 and P =.33, respectively]). A statistically significant increase in total higher-order wavefront aberrations was observed following flap formation (root mean square pre-flap 0.344 +/- 0.125 and post-flap 0.440 +/- 0.221 [P =.04]). CONCLUSION Flap formation during LASIK can modify the eye's existing natural higher-order aberrations (especially spherical and coma-like aberrations along the axis of the flap's hinge), while visual acuity and refractive error remain unaffected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Topography-guided neutralization technique for the management of flap complication in laser in situ keratomileusis

A 29-year-old male was referred following a flap loss after the creation of a thin, irregular flap with a visual acuity of logMAR 0.1 with -2.0 DS-2.75 DC × 175°. Corneal topography and anterior segment optical coherence tomography revealed an irregular corneal curvature and epithelial profile. Phototherapeutic keratectomy (PTK) followed by Topography - Guided Custom Ablation Treatment (TCAT), ...

متن کامل

Optical Aberrations Following Laser In Situ Keratomileusis (LASIK) Surgery

| Introduction | Methods | Results | Discussion | Acknowledgments

متن کامل

Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia.

PURPOSE To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality. METHODS Total and corneal aberrations were measured before and after standard hyperopic LASIK in 13 eyes (preoperative spherical equivalent refractive error +3.17 +/- 1.10 D). The Chiron Technolas 217C laser with PlanoScan was used. Total aberrations (measur...

متن کامل

Incidence and Outcomes of Anterior Chamber Gas Bubble during Femtosecond Flap Creation for Laser-Assisted In Situ Keratomileusis

Purpose. To report the incidence and outcomes of anterior chamber gas bubble formation during femtosecond laser flap creation for laser-assisted in situ keratomileusis (LASIK). Methods. The charts of 2,886 consecutive eyes that underwent femtosecond LASIK from May 2011 through August 2014 were retrospectively reviewed. The incidence, preoperative characteristics, intraoperative details, and pos...

متن کامل

Advances in refractive surgery: microkeratome and femtosecond laser flap creation in relation to safety, efficacy, predictability, and biomechanical stability.

PURPOSE OF REVIEW Methods of flap creation have changed over the years from the evolution of the mechanical microkeratome to the introduction of the IntraLase femtosecond laser keratome, both of which have different mechanisms of action to create corneal resections. Previous studies report the advantages and disadvantages of the mechanical microkeratome and the IntraLase femtosecond laser. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 28 10  شماره 

صفحات  -

تاریخ انتشار 2002