Development of high-sensitivity ion trap ion mobility spectrometry time-of-flight techniques: a high-throughput nano-LC-IMS-TOF separation of peptides arising from a Drosophila protein extract.

نویسندگان

  • Sunnie Myung
  • Young Jin Lee
  • Myeong Hee Moon
  • John Taraszka
  • Rena Sowell
  • Stormy Koeniger
  • Amy E Hilderbrand
  • Stephen J Valentine
  • Lucy Cherbas
  • Peter Cherbas
  • Thomas C Kaufmann
  • David F Miller
  • Yehia Mechref
  • Milos V Novotny
  • Michael A Ewing
  • C Ray Sporleder
  • David E Clemmer
چکیده

A linear octopole trap interface for an ion mobility time-of-flight mass spectrometer has been developed for focusing and accumulating continuous beams of ions produced by electrospray ionization. The interface improves experimental efficiencies by factors of approximately 50-200 compared with an analogous configuration that utilizes a three-dimensional Paul geometry trap (Hoaglund-Hyzer, C. S.; Lee, Y. J.; Counterman, A. E.; Clemmer, D. E. Anal. Chem. 2002, 74, 992-1006). With these improvements, it is possible to record nested drift (flight) time distributions for complex mixtures in fractions of a second. We demonstrate the approach for several well-defined peptide mixtures and an assessment of the detection limits is given. Additionally, we demonstrate the utility of the approach in the field of proteomics by an on-line, three-dimensional nano-LC-ion mobility-TOF separation of tryptic peptides from the Drosophila proteome.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiplexed ion mobility spectrometry-orthogonal time-of-flight mass spectrometry.

Ion mobility spectrometry (IMS) coupled to orthogonal time-of-flight mass spectrometry (TOF) has shown significant promise for the characterization of complex biological mixtures. The enormous complexity of biological samples (e.g., from proteomics) and the need for both biological and technical analysis replicates imposes major challenges for multidimensional separation platforms with regard t...

متن کامل

Development of high throughput dispersive LC-ion mobility-TOFMS techniques for analysing the human plasma proteome.

A technique that combines ion mobility spectrometry (IMS) with reversed-phase liquid chromatography (LC), collision-induced dissociation (CID) and mass spectrometry (MS) has been developed. The approach is described as a high throughput means of analysing complex mixtures of peptides that arise from enzymatic digestion of protein mixtures. In this approach, peptides are separated by LC and, as ...

متن کامل

Dynamically multiplexed ion mobility time-of-flight mass spectrometry.

Ion mobility spectrometry-time-of-flight mass spectrometry (IMS-TOFMS) has been increasingly used in analysis of complex biological samples. A major challenge is to transform IMS-TOFMS to a high-sensitivity, high-throughput platform, for example, for proteomics applications. In this work, we have developed and integrated three advanced technologies, including efficient ion accumulation in an io...

متن کامل

Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Ion mobility spectrometry (IMS) has been explored for decades, and its versatility in separation and identification of gas-phase ions is well established. Recently, field asymmetric waveform IMS (FAIMS) has been gaining acceptance in similar applications. Coupled to mass spectrometry (MS), both IMS and FAIMS have shown the potential for broad utility in proteomics and other biological analyses....

متن کامل

Development of high-throughput liquid chromatography injected ion mobility quadrupole time-of-flight techniques for analysis of complex peptide mixtures.

The development of a multidimensional approach involving high-performance liquid chromatography (LC), ion mobility spectrometry (IMS) and tandem mass spectrometry is described for the analysis of complex peptide mixtures. In this approach, peptides are separated based on differences in their LC retention times and mobilities (as ions drift through He) prior to being introduced into a quadrupole...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 75 19  شماره 

صفحات  -

تاریخ انتشار 2003