Influence of static alignment of the knee, range of tibial rotation and tibial plateau geometry on the dynamic alignment of "knee-in" and tibial rotation during single limb drop landing.

نویسندگان

  • Takahiro Arai
  • Hiroichi Miaki
چکیده

BACKGROUND Dynamic alignment of "knee-in & toe-out" is a risk factor for anterior cruciate ligament injury and is possibly influenced by static knee alignment, range of tibial rotation and tibial plateau geometry. METHODS Twenty-eight healthy women were classified into valgus, neutral and varus groups based on static alignment of their knees. A 3-dimensional motion analysis was carried out for a single limb drop landing. The range of tibial rotation and posterior tibial slope angle was measured by MRI. Comparison among the 3 groups and correlation between the angles was analyzed during motion. FINDINGS The differences between the medial and lateral posterior tibial slope angles were greater (P=0.019), also range of internal tibial rotation for the valgus group (P=0.017) and, for the varus group, the "knee-in" angle (P=0.048). The "knee-in" angle correlated significantly with the tibial rotation angle (R=-0.39, P=0.038), and the range of tibial rotation correlated with the variations between the medial and lateral posterior tibial slope angles (R=0.90, P=0.003). INTERPRETATION The range of tibial rotation, posterior tibial slope and "knee-in" angle varied according to whether the knee was in valgus or varus with the range of tibial rotation dependent on the posterior tibial slope angle. The greater the "knee-in" angle became, the smaller the internal tibial rotation was, acting in a kinetic chain. The results suggest that static alignment of the knee may be utilized as a predictor for potential problems that occur during motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Relationship of Anatomical Alignment and Strength of Some Lower Extremity Muscles with Jump-landing Biomechanics: A Landing Error Scoring System Study

Background: The purpose of the present study was to investigate correlative and predictive relationship of lower extremity anatomical alignment, isometric hip abduction and external rotation strength with jump-landing biomechanics using Landing Error Scoring System (LESS). Methods: Anatomical alignment and isometric lower extremity muscle strength of 30 active...

متن کامل

Functional Outcome and Incidence of Osteoarthritis in Operated Tibial Plateau Fractures

Background: In the challenging tibial condyle fractures despite anatomical joint reconstruction, development ofosteoarthritis may still occur secondary to the initial articular cartilage and meniscal injury. The aim of the study wasto know incidence of osteoarthritis in our operated cases of tibial plateau fracture and to evaluate functional outcome.Methods: Our operated 60 patients of tibial p...

متن کامل

Anatomical Alignment of Lower Extremity in Subjects With Genu Valgum and Genu Varum Deformities

Purpose: Changes in lower extremity alignment in individuals with abnormality of this segments are unclear. The present study aimed to compare lower extremity alignment in subjects with genu valgum and genu varum deformities and healthy subjects  in order to understand the lower extremity alignment changes in this group.  Methods: This was a causal-comparative study. The sample comprised 120 m...

متن کامل

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

متن کامل

Combined Rotational Alignment Change after Total Knee Arthroplasty in Different Tibial Component Designs: Implications for Optimal Tibial Component Rotational Alignment

Purpose The rotational alignment of the femoral and tibial components is closely related to the results after total knee arthroplasty (TKA). In this study, we measured the combined rotational alignment change (ΔCR) after TKA and compared the different influence of symmetric and asymmetric tibial component designs on the combined rotational alignment. Materials and Methods Eighty-four patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biomechanics

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2013