The use of robotic endovascular catheters in the facilitation of transcatheter aortic valve implantation.

نویسندگان

  • Radoslaw A Rippel
  • Alex E Rolls
  • Celia V Riga
  • Mohamad Hamady
  • Nicholas J Cheshire
  • Colin D Bicknell
چکیده

OBJECTIVES The use of transcatheter aortic valve implantation (TAVI) is rapidly increasing with advances in technology and improved clinical outcomes. Adoption of robotic catheter technologies could have a role in TAVI, in different stages of the procedure, to improve endovascular tool manipulation and potentially reduce the risk of cerebral embolization. The aim was to determine whether there are advantages in using a robotic catheter for TAVI in the initial stages of the procedure; aortic arch navigation and valve crossing. METHODS A silicone in vitro model of the aorta and stenotic aortic valve was developed. Fifteen operators performed the fluoroscopy-guided simulation using manual and robotic techniques. Performance metrics-time and vessel wall contact (wall-hits) were compared (Wilcoxon's signed-rank test). RESULTS Overall, the time taken for robotic arch navigation was increased (3.09 min interquartile range (1.24-6.29) vs 1.21 min (0.15-4.42); P = 0.03). Contact with the aortic arch wall, however, significantly decreased using the robotic catheter: wall-hits 1 (0-5) vs 6 (2-22), P < 0.01. For valve crossing, there was no significant increase in time and wall-hits when using the robotic technology. CONCLUSIONS Use of robotic catheter technology is feasible in the initial stages of TAVI. Although it takes longer, robotic navigation reduces contact with the aortic arch wall, potentially reducing the embolic risk during endovascular manipulation. Using a robotic catheter is possible without increasing the number of wall-hits during valve crossing. This may provide a stable platform for wire positioning in the ventricle. With improvements in technology, perhaps allowing valve deployment, the stability and accuracy of the robotic arm may further improve performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Transfemoral transcatheter aortic valve implantation in a patient with multiple endovascular aortic stents – a case report

BACKGROUND In patients undergoing transfemoral transcatheter aortic valve implantation, previous endovascular interventions bear a risk for the valve frame to get stucked to the aortic stents. CASE PRESENTATION We report on a 75-year-old frail patient with severe aortic stenosis and a rapid increase of an infra-renal aneurysm. He had a history of multiple endovascular interventions on the aor...

متن کامل

Axillary approach for transcatheter aortic valve implantation: optimization of the endovascular treatment for the aortic valve stenosis.

INTRODUCTION AND OBJECTIVES To validate the axillary approach as a safe and efficient option for the transcatheter aortic valve implantation in patients who have contraindication for femoral approach at three Spanish hospitals. METHODS We included patients with severe symptomatic aortic stenosis at very high or prohibitive surgical risk, selected by a multidisciplinary team, for transcatheter...

متن کامل

Impact of aortic regurgitation after transcatheter aortic valve implantation: results from the REVIVAL trial.

OBJECTIVES Understanding the severity of aortic regurgitation (AR) after transcatheter aortic valve implantation, its impact on left ventricular (LV) structure and function, and the structural factors associated with worsening AR could lead to improvements in patient selection, implantation technique, and valve design. BACKGROUND Initial studies in patients at high risk of surgical aortic val...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 45 5  شماره 

صفحات  -

تاریخ انتشار 2014