Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys.

نویسندگان

  • Hao Song
  • Dan Ruan
  • Wenyang Liu
  • V Andrew Stenger
  • Rolf Pohmann
  • Maria A Fernández-Seara
  • Tejas Nair
  • Sungkyu Jung
  • Jingqin Luo
  • Yuichi Motai
  • Jingfei Ma
  • John D Hazle
  • H Michael Gach
چکیده

PURPOSE Respiratory motion prediction using an artificial neural network (ANN) was integrated with pseudocontinuous arterial spin labeling (pCASL) MRI to allow free-breathing perfusion measurements in the kidney. In this study, we evaluated the performance of the ANN to accurately predict the location of the kidneys during image acquisition. METHODS A pencil-beam navigator was integrated with a pCASL sequence to measure lung/diaphragm motion during ANN training and the pCASL transit delay. The ANN algorithm ran concurrently in the background to predict organ location during the 0.7-s 15-slice acquisition based on the navigator data. The predictions were supplied to the pulse sequence to prospectively adjust the axial slice acquisition to match the predicted organ location. Additional navigators were acquired immediately after the multislice acquisition to assess the performance and accuracy of the ANN. The technique was tested in eight healthy volunteers. RESULTS The root-mean-square error (RMSE) and mean absolute error (MAE) for the eight volunteers were 1.91 ± 0.17 mm and 1.43 ± 0.17 mm, respectively, for the ANN. The RMSE increased with transit delay. The MAE typically increased from the first to last prediction in the image acquisition. The overshoot was 23.58% ± 3.05% using the target prediction accuracy of ± 1 mm. CONCLUSION Respiratory motion prediction with prospective motion correction was successfully demonstrated for free-breathing perfusion MRI of the kidney. The method serves as an alternative to multiple breathholds and requires minimal effort from the patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A patient-adapted navigator tracking approach for prospective 3D respiratory motion correction in free-breathing myocardial perfusion imaging

H. Pedersen, S. Ringgaard, W. Y. Kim The MR Research Centre, Skejby Hospital, Aarhus University Hospital, Aarhus N, Denmark INTRODUCTION Quantitative analysis of myocardial perfusion using free-breathing first-pass perfusion MRI is degraded by respiratory induced motion of the heart. Conventional strategies to correct this motion include the manual alignment of each image to fit a reference ima...

متن کامل

Free-breathing myocardial perfusion MRI using SW-CG-HYPR and motion correction.

First-pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate-gradient (CG) highly constrained back-projection reconstruction (HYPR) (SW-CG-HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath-hold. This work presents a non-model-base...

متن کامل

Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling.

PURPOSE To develop a navigator technique enabling free-breathing acquisition to afford sufficient signal averaging for quantitative renal perfusion measurement using arterial spin labeling MRI. METHODS A novel two-dimensional (2D) navigator technique was implemented in concert with flow-sensitive alternating inversion recovery (FAIR) preparation and true fast imaging with steady precession (T...

متن کامل

Comparison of three diffusion encoding schemes for cardiac imaging under free breathing conditions.

Background Diffusion cardiac imaging has been challenging due to respiratory and heart motion. Recent developments in cardiac diffusion imaging proposed more robust spin echoes encoding scheme, like Acceleration Motion Correction(AMC)(1), to tackle cardiac motion. In addition, free breathing acquisition with prospective motion correction like slice following technique (2) has been shown to redu...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2017