Simultaneous study of subcellular exocytosis with individually addressable multiple microelectrodes.

نویسندگان

  • Jun Wang
  • Andrew G Ewing
چکیده

We report the application of individually addressable microelectrode arrays (MEAs) to study the heterogeneity of cell exocytosis at the subcellular level. Multiple subcellular-size electrodes are covered by a single PC12 cell for the investigation of subcellular exocytosis. PC12 cells have been seeded and cultured on top of three kinds of MEAs containing 16, 25, or 36 square microelectrodes (4 μm width in a 4 by 4 MEA, 3 μm width in a 5 by 5 MEA, 2 μm width in a 6 by 6 MEA). After collagen coating, single cells were found to cover several electrodes and these were selected for the study of subcellular exocytosis. Amperometric results show that single cell and subcellular heterogeneity in single cell exocytosis can be electrochemically detected with these MEAs. The results also show that these MEAs are suitable for detecting fast chemical events at single cells, as well as for developing multifunctional electrochemical sensors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatial Resolution of Single-Cell Exocytosis by Microwell-Based Individually Addressable Thin Film Ultramicroelectrode Arrays

We report the fabrication and characterization of microwell-based individually addressable microelectrode arrays (MEAs) and their application to spatially and temporally resolved detection of neurotransmitter release across a single pheochromocytoma (PC12) cell. The microwell-based MEAs consist of 16 4-μm-width square ultramicroelectrodes, 25 3-μm-width square ultramicroelectrodes, or 36 2-μm-w...

متن کامل

Bioelectrochemical Imaging with Micro/Nanoelectrode Systems

This paper report a novel approach for bioimaging with two different micro/nanoelectrode systems; i. e., scanning electrochemical microscopy (SECM) and individually addressable microelectrode array. Hybrid SECM systems with shear-force or ion-conductance feedback distance control were applied to high resolution and simultaneous imaging of topography and electrochemical responses of enzymes and ...

متن کامل

Addressable Electrode Array Device Incorporated with Ida Electrodes for Biological Analyses

In the past decade, several kinds of microelectrode arrays have been applied to chemical and biological analyses. These electrochemical array devices have substantial advantages, including rapid response time and qualitative and quantitative detection. Among the various systems that are based on electrochemical detection, individually addressable electrode arrays have been used for simultaneous...

متن کامل

I-6: Role of Actin Cytoskeleton during Mouse Sperm Acrosomal Exocytosis

Background: Mammalian sperm must undergo a process termed capacitation to become competent to fertilize an egg. Capacitation renders the sperm competent by priming the cells to undergo a rapid exocytotic event called acrosomal exocytosis that is stimulated by the zona pellucida (ZP) of the egg or progesterone. Over the years, several biochemical events have been associated with the capacitation...

متن کامل

Designing Electroactive Biointerface for Spatiotemporal Control of Cell Attachment and Release

In this paper, we demonstrate the use of individually addressable microelectrodes for cell sorting and cell micropatterning applications. Microelectrodes were modified with cell adhesive or non-adhesive molecules and then electrically stimulated to selectively adsorb or desorb proteins and/or mammalian cells. The switching of the surface properties was achieved by the electrochemical desorption...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 13  شماره 

صفحات  -

تاریخ انتشار 2014