Assessment of radiofrequency device sensitivity for the detection of retained surgical sponges in patients with morbid obesity.

نویسندگان

  • Victoria M Steelman
  • Mohammad H Alasagheirin
چکیده

HYPOTHESIS Retained surgical sponges are serious medical errors that result in negative patient outcomes. A radiofrequency (RF) mat for the operating room bed has recently been introduced to detect the presence of a retained surgical sponge. The study objectives were to evaluate the sensitivity and specificity of the RF mat for the detection of surgical sponges through the torso of individuals with varying body habitus and to compare the sensitivity of the RF mat with that of the RF wand. We hypothesized that the sensitivity and specificity of the RF technology would be comparable to published findings of the manual sponge count by operating room personnel. DESIGN A prospective, crossover, double-blinded study design was used. Participants served as their own controls. SETTING Large Midwestern academic medical center. PARTICIPANTS In total, the first phase of the study enrolled 203 participants, including 129 (63.5%) with morbid obesity. One hundred seventeen of 203 participants were also enrolled in the second phase of the study. MAIN OUTCOME MEASURES The study participants reclined in a supine position on top of an RF mat. Four surgical sponges were sequentially placed on top of the torso in locations approximating the abdominal quadrants. The torso was scanned for sponges. In a subset of participants, 4 surgical sponges were sequentially placed underneath the torso, and an RF wand was passed over the abdomen. RESULTS Overall, 812 readings were obtained with the RF mat, and 468 readings were obtained with the RF wand. Twelve false-negative readings were obtained with the RF mat, exclusively in participants with super morbid obesity (body mass index [calculated as weight in kilograms divided by height in meters squared] >50.0). Overall, the sensitivity of the RF mat was 98.1%, and the specificity of the RF mat was 100.0%. In the subset of 117 participants in whom the RF wand was also used, the sensitivity and specificity of the wand were each 100.0%. CONCLUSIONS The sensitivity and specificity of RF device technology are much higher than those of surgical sponge counts or published findings on the use of intraoperative radiographs to identify retained surgical sponges. The RF wand is more sensitive than the RF mat in individuals with morbid obesity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Significant results of using laparoscopic adjustable gastric banding (LAGB) for the treatment of morbid obesity

Background: Morbid obesity contributes to many health risks including physical, emotional, and social problems. The increasing prevalence of obesity is a major public health concern since obesity is associated with several chronic diseases. Morbid obesity is one of the biggest independent risk factors for early mortality. Various options for the surgical treatment of morbid obesity have bee...

متن کامل

Psychometric Properties of Quality of Life Assessment Tools in Morbid Obesity: A Review of Literature

Background: Since studies have demonstrated that morbid obesity can exponentially impair quality of life, the measurement of quality of life is paramount to monitoring the effects of treatment and influences the development of clinical pathways, service provision, healthcare expenditures, and public health policy. Accordingly, clinicians, researchers, and policy makers must rely on valid instru...

متن کامل

Assessment of Pathological Findings of the Stomach in Morbid Obese Patients who are Candidates for Bariatric Surgery and the Association with Helicobacter Pylori, Biochemical Status and Inflammatory Factors

Abstract Introduction: Obesity and upper gastrointestinal disorders are the public health problems in the world and Iran. The role of routine preoperative upper gastrointestinal endoscopy of the morbid obese patients undergoing bariatric surgery is a subject of discussion. The aim of this study was to determine the relationship between gastric pathological findings in morbid obese patients w...

متن کامل

Retained surgical sponges, needles and instruments

INTRODUCTION Retained sponges and instruments (RSI) due to surgery are a recognised medical 'never event' and have catastrophic implications for patients, healthcare professionals and medical care providers. The aim of this review was to elucidate the extent of the problem of RSI and to identify preventative strategies. METHODS A comprehensive literature search was performed on MEDLINE(®), Em...

متن کامل

Cost-effectiveness of Laparoscopic Sleeve Gastrectomy and Laparoscopic Roux-en-Y Gastric Bypass in Patients with Morbid Obesity: A Systematic Review

Cost-effectiveness of Laparoscopic Sleeve Gastrectomy and Laparoscopic Roux-en-Y Gastric Bypass in Patients with Morbid Obesity: A Systematic Review Talebianpour Hamid1, Shahab Alizadeh2*   1. Ph.D. Student, School of Public Health, Department of Management Sciences and Health Economics, Tehran University of Medical Sciences, Tehran, Iran 2. Ph.D. Student, Faculty of Nutrition and Dietetic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of surgery

دوره 147 10  شماره 

صفحات  -

تاریخ انتشار 2012