Central venous catheters--the inability of 'intra-atrial ECG' to prove adequate positioning.
نویسندگان
چکیده
BACKGROUND The classic increase in P wave size, known as 'P-atriale', is a widely accepted criterion for determination of proper positioning of central venous catheter tips. Recent transoesophageal echocardiography (TOE) studies did not confirm intra-atrial position despite advancing the central venous catheter further than indicated by ECG guidance. We postulate that the pericardial reflection rather than the entry into the right atrium corresponds to the ECG changes. In order to test our hypothesis we sought to determine the anatomical substrate for the electrical changes in an animal study. Subsequently, a modified version of the study was undertaken in man and is also reported. METHODS In six juvenile pigs the left external jugular vein and right carotid artery were cannulated. A triple-lumen central venous catheter was positioned by ECG guidance using a Seldinger wire as an exploring electrode. The venous and arterial catheters were suture fixed 2 cm beyond the onset of an increase in P wave size. The corresponding anatomical catheter tip position was determined by open exploration of the vessels and the heart. Subsequently the catheter tip position (during advancement) of a pulmonary artery catheter and the corresponding electrical ECG changes were examined in 10 patients during open chest cardiac surgery. RESULTS All catheters-arterial and venous, in animals and humans-revealed an increase in size of the P wave as well as the QRS complex. All venous catheters were positioned in the superior vena cava, beyond the pericardial reflection but outside the right atrium. All arterial catheters were positioned in the ascending aorta thus also beyond the pericardial reflection. CONCLUSIONS The start of an increase in P wave size does not correspond with the entrance of the right atrium. The anatomic equivalent for the electrophysiological changes of the ECG is the pericardial reflection. ECG guidance is unable to distinguish between venous and arterial catheter position.
منابع مشابه
Optimal positioning of right-sided internal jugular venous catheters: Comparison of intra-atrial electrocardiography versus Peres' formula
Central venous catheters are routinely placed in patients undergoing major surgeries where expected volume and hemodynamic disturbances are likely consequences. The incorrect positioning may give false central venous pressure (CVP) readings leading to incorrect volume replacement and other serious complications. 50 American Society of Anaesthesiologists grade II-IV patients aged 18-60 years wer...
متن کاملExternal Jugular Vein Catheterization Using 'Intra-Atrial Electrocardiogram'
PURPOSE To investigate the reliability of intra-atrial electrocardiogram (ECG) use for external jugular vein (EJV) catheterization. MATERIALS AND METHODS Patients undergoing open heart surgery in Suleyman Demirel University Hospital between February and June 2006 were included in the study. Using a sterile Seldinger technique, a triple lumen polyurethane central venous catheter was introduced...
متن کاملLocation of the Central Venous Catheter Tip With Bedside Ultrasound in Young Children: Can We Eliminate the Need for Chest Radiography?
OBJECTIVE To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. DESIGN Prospective observational study. SETTING PICU of a university hospital. PATIENTS Patients aged 0-14 who required a central venous catheter. INTERVENTION None. MEASUREMENTS AND MAIN RESULTS Central venous catheter tip location was confirmed by ultrasound an...
متن کاملThe intracavitary ECG method for positioning the tip of central venous catheters: results of an Italian multicenter study.
PURPOSE The aim of this multicenter study was to assess the feasibility, safety, and accuracy of the intracavitary ECG method for real-time positioning of the tip of different types of central venous catheters. METHODS A total of 1444 catheter insertions in adult patients were studied in eight Italian centers (539 ports, 245 PICCs, 325 tunneled CVCs, 335 non-tunneled CVCs). Patients with no v...
متن کاملThe accuracy of electrocardiogram-controlled central line placement.
BACKGROUND Electrocardiogram (ECG) guidance to confirm accurate positioning of central venous catheters (CVC), placed before surgery in the operating room, is rarely used in the United States. We designed this randomized, controlled trial to investigate whether the use of this technique impacts the accuracy of CVC placement. METHODS Patients in group ECG (n = 147) had a CVC placed using right...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 93 2 شماره
صفحات -
تاریخ انتشار 2004